PGVA Manual
Festo SE & Co. KG
Page 12 of 20
Man mode
ADDR: 0x115
Input register 0
1
0: Device is not
in manufacturing
mode
1: Device is in
manufacturing
mode
Valve actuation
time
ADDR: 0x1000
Holding
register
Dimension:
ms
0 1
Reading this
register will
always return:
0xFFFF.
Actuate output
electromagnetic valve with a
period matching value to
write in Modbus frame
Note: output
electromagnetic valve is an
option for the product - it
might be installed on devices
used to demonstrations
Vacuum
threshold
*
ADDR: 0x1001
(lowest
pressure at
which vacuum
pump is
deactivated
after regulating
vacuum tank
pressure)
Holding
register
Dimension:
mbar
When
writing:
1124.5
When
reading: -
1498.334
When
writing:
0.7505
When
reading:
1.332
Returns vacuum
threshold
Sets vacuum threshold.
Note: the SW implements
hysteresis in vacuum
regulator - the value from
Modbus command is applied
immediately but, in some
cases, if the change is in
lower than hysteresis the
device will react at the
moment pressure reached
the vacuum threshold
Pressure
threshold
*
ADDR: 0x1002
(highest
pressure at
which air pump
is deactivated
after filling up
pressure tank)
Holding
register
Dimension:
mbar
When
writing:
1124.5
When
reading: -
1498.334
When
writing:
0.7505
When
reading:
1.332
Returns pressure
threshold
Sets pressure threshold.
Note: the SW implements
hysteresis in pressure
regulator - the value from
Modbus command is applied
immediately but, in some
cases, if the change is in
lower than hysteresis the
device will react at the
moment pressure reached
the threshold
Output
pressure
ADDR: 0x1003
(output
pressure set
point value)
Holding
register
Dimension:
mbar
When
writing:
2047.5
When
reading: -
500
When
writing:
4.095
When
reading:
0.244
Returns output
pressure set
point value
Sets output pressure set
point value.
Note: The set point value is
applied for less than 2.5ms
after the Modbus command
is received. However, the
output pressure regulator
will need some time to
regulate the output value.
This time depends on the
difference between new and