11
Accessories
Name
OVEM−05
OVEM−07/10
OVEM−14
Connecting cable M12x1, 5−pin, 2.5m
NEBU−M12G5−K−2.5−LE5
Connecting cable M12x1, 5−pin, 5m
NEBU−M12G5−K−5−LE5
H−rail mounting
OABM−H
Mounting bracket
HRM−1
Silencer extension
UOMS−¼
UOMS−¼
Common supply manifold
OABM−P−4
pp y
OABM−P−6
OABM−P−8
Blanking plug
OASC−G1−P
Fig.20 Accessories
12
Technical data
OVEM
−05
−07/−10
−14
Operating pressure
[bar]
2
Ū
8
Operating pressure
[bar]
QS/GN/PL−
Ū
−1P/1N: 2
Ū
6
Operating medium
Filtered, unlubricated compressed air,
grade of filtration 40
ì
m
Ambient temperature
[°C]
0
Ū
50
Temperature of medium
[°C]
0
Ū
50
Nominal operating voltage
[V DC]
24 ±15%
Idle current
1)
[mA]
<
80
Coil characteristics 24 V DC
[W]
Low−current phase: 0.3
[ ]
High−current phase: 2.55
Time until current reduction
[ms]
<
80
Ready−state delay
[ms]
≤
500
Switching output
Max. output current
[mA]
100
Voltage drop
[V]
≤
1.5
Capacitive load max. DC
[nF]
≤
100
Reaction time
[ms]
<
12
≤
22
≤
35
Protective functions
Inductive protective circuit
Adapted to MZ, MY, ME coils
Protection against short circuit
Yes
Overload protection
Yes
Reverse polarity protection
For all electrical connections
Protection class
IP65
Electrical protection class
3
Interference immunity
See declaration of conformity (www.festo.com)
Interference emission
See declaration of conformity (www.festo.com)
Vibration resistance
As per DIN/IEC 68/EN 60068 part 2−6:
0.35 mm travel at 10
Ū
60 Hz,
5 g acceleration at 60
Ū
150 Hz
Shock resistance
As per DIN/IEC 68/EN 60068 part 2−27:
30 g acceleration at 11ms duration (half−sine)
Max. permitted signal line length
[m]
30
Overload pressure at vacuum port
[bar]
1P/1N:
≤
5
Overload pressure at vacuum port
[bar]
Without vacuum sensor:
≥
10
Pressure measuring range
3)
[bar]
1
Ū
0
Repetition accuracy of switching
value
2)3)
[% FS]
Max. ±0.3
Temperature co−efficient
2)3)
[% FS/K] ±0.05
Setting range for threshold values
3)
[bar]
1
Ū
0
Hysteresis, fixed
3)
[mbar]
20
1)
Both solenoid valves are actuated
2)
% FS = % of the final value in the measuring range (full−scale)
3)
Technical feature only relevant for models with vacuum sensor
Fig.21 Technical data