Variant
Switching output
Switching inputs
−1P
Switching output
positive switching
Switching inputs
positive switching
−1N
Switching output
negative switching
Switching inputs
negative switching
Fig.5
Variants, switching output and switching inputs
2.3 Switching point SP and hysteresis Hy
Threshold value comparator
NO (normally open)
Fig.6
Settings for switching points (SP), hysteresis (Hy) and buffer (FR)
Note
The switching point is derived from the Teach pressure and the buffer. A buffer
(35% of the Teach pressure) is deducted from the Teach pressure (SP = TP
0.35*TP). For example, with a Teach pressure of 0.5bar, a switching point of
0.33bar is set.
The hysteresis has a fixed value.
3
Requirements for product use
Note
Improper handling can result in malfunctions.
· Make sure that the following specifications are always observed.
· Compare the maximum values specified in these operating instructions with
your actual application (e.g. operating media, pressures, forces, torques, tem
peratures, masses, speeds, operating voltages, flow rates).
· Take into consideration the ambient conditions at the location of use.
· Please comply with national and local safety laws and regulations.
· Remove all transport packing such as protective wax, plastic wrap (polyamide),
caps (polyethylene), cardboard boxes (except for the covers on the pneumatic
ports).
The packing is intended for recycling (except for: oiled paper = general waste).
· Use the product in its original state. Unauthorised modification is not permitted.
4
Installation
The product can be fitted in any position. Mount the vacuum generator and con
nect its tubing in such a way that no condensation from the compressed air lines
can gather in the device.
4.1 Mechanical
Direct mounting
Fig.7
Direct mounting
· Mount the vacuum generator at the intended position with two screws (size of
the mounting screws
Fig.8); fasten with max. torque 2.5Nm.
We recommend that suitable washers be used.
or
· Mount the vacuum generator on its back cover with 4 screws, size M3, with max.
torque 0.8Nm.
OVEM
Size of mounting screws
05/07/10
M5
14
M4
Fig.8
Size of mounting screws
Mounting with accessories
With H−rail mounting kit
1
Fig.9
H−rail mounting
1. Mount the H−rail mounting on the back cover of the vacuum generator with
4screws, size M3, with max. torque 0.8Nm.
2. Hook the vacuum generator onto the H−rail and press in the direction of the
arrow.
3. Secure the vacuum generator to the H−rail with screw
1
, fastening it with max.
torque 1Nm.
With mounting bracket
Fig.10 Mounting bracket
· Mount the vacuum generator at the intended position with two screws
(size of the mounting screws
Fig.8); fasten with max. torque 2.5Nm.
We recommend that suitable washers be used.
The vacuum generator can also be mounted on a common supply manifold with up
to 8 positions. Information on mounting
è
Assembly instructions OABM−P−
Ū
.
OVEM−
Ū
Type of mounting
Q−/−G−
With screws or accessories,
è
Accessories
−P−
With common supply manifold,
è
Accessories
Fig.11 Key feature Mounting type
4.2 Pneumatic
· Connect appropriate tubing to the QS push−in connectors (−QS, −QO, −PL, −PO).
We recommend that tubing of type PUN−6 be used.
· When selecting the tubing for tubing connection on a vacuum generator with
threaded ports (−GN, −GO), be mindful of the minimum internal diameter for
tubing stated in Fig.12.