background image

Variant

Switching  output

Switching  inputs

−1P

Switching   output
positive  switching

Switching  inputs
positive  switching

−1N

Switching  output
negative  switching

Switching  inputs
negative  switching

Fig.5

Variants,  switching  output  and  switching  inputs

2.3 Switching  point  SP  and  hysteresis  Hy

Threshold  value  comparator

NO  (normally  open)

Fig.6

Settings  for  switching  points  (SP),  hysteresis  (Hy)  and  buffer  (FR)

Note

The  switching  point  is  derived  from  the  Teach  pressure  and  the  buffer.  A  buffer
(35%  of  the  Teach  pressure)  is  deducted  from  the  Teach  pressure  (SP  =  TP  
0.35*TP).  For  example,  with  a  Teach  pressure  of  0.5bar,  a  switching  point  of
0.33bar  is  set.
The  hysteresis  has  a  fixed  value.

3

Requirements  for  product  use

Note

Improper  handling  can  result  in  malfunctions.
· Make  sure  that  the  following  specifications  are  always  observed.

· Compare  the  maximum  values  specified  in  these  operating  instructions  with

your  actual  application  (e.g.  operating  media,  pressures,  forces,  torques,  tem
peratures,  masses,  speeds,  operating  voltages,  flow  rates).

· Take  into  consideration  the  ambient  conditions  at  the  location  of  use.
· Please  comply  with  national  and  local  safety  laws  and  regulations.
· Remove  all  transport  packing  such  as  protective  wax,  plastic  wrap  (polyamide),

caps  (polyethylene),  cardboard  boxes  (except  for  the  covers  on  the  pneumatic
ports).
The  packing  is  intended  for  recycling  (except  for:  oiled  paper  =  general  waste).

· Use  the  product  in  its  original  state.  Unauthorised  modification  is  not  permitted.

4

Installation

The  product  can  be  fitted  in  any  position.  Mount  the  vacuum  generator  and  con
nect  its  tubing  in  such  a  way  that  no  condensation  from  the  compressed  air  lines
can  gather  in  the  device.

4.1 Mechanical

Direct  mounting

Fig.7

Direct  mounting

· Mount  the  vacuum  generator  at  the  intended  position  with  two  screws  (size  of

the  mounting  screws 

è

Fig.8);  fasten  with  max.  torque  2.5Nm.

We  recommend  that  suitable  washers  be  used.
or

· Mount  the  vacuum  generator  on  its  back  cover  with  4  screws,  size  M3,  with  max.

torque  0.8Nm.

OVEM

Size  of  mounting  screws

05/07/10

M5

14

M4

Fig.8

Size  of  mounting  screws

Mounting  with  accessories

With  H−rail  mounting  kit

1

Fig.9

H−rail  mounting

1. Mount  the  H−rail  mounting  on  the  back  cover  of  the  vacuum  generator  with

4screws,  size  M3,  with  max.  torque  0.8Nm.

2. Hook  the  vacuum  generator  onto  the  H−rail  and  press  in  the  direction  of  the

arrow.

3. Secure  the  vacuum  generator  to  the  H−rail  with  screw 

1

,  fastening  it  with  max.

torque  1Nm.

With  mounting  bracket

Fig.10 Mounting  bracket

· Mount  the  vacuum  generator  at  the  intended  position  with  two  screws 

(size  of  the  mounting  screws 

è

Fig.8);  fasten  with  max.  torque  2.5Nm.

We  recommend  that  suitable  washers  be  used.

The  vacuum  generator  can  also  be  mounted  on  a  common  supply  manifold  with  up
to  8  positions.  Information  on  mounting 

è

Assembly  instructions  OABM−P−

Ū

.

OVEM−

Ū

Type  of  mounting

Q−/−G−

With  screws  or  accessories, 

è

Accessories

−P−

With  common  supply  manifold, 

è

Accessories

Fig.11 Key  feature    Mounting  type

4.2 Pneumatic

· Connect  appropriate  tubing  to  the  QS  push−in  connectors  (−QS,  −QO,  −PL,  −PO).

We  recommend  that  tubing  of  type  PUN−6  be  used.

· When  selecting  the  tubing  for  tubing  connection  on  a  vacuum  generator  with

threaded  ports  (−GN,  −GO),  be  mindful  of  the  minimum  internal  diameter  for
tubing  stated  in  Fig.12.