MS6-SV-...-E-10V24
70
Festo – MS6-SV-...-E-10V24 – 1310b English
Type
MS6-SV-E
Switching point
Approx. 50 % of p1
Fig. 11
Filling flow
Adjustable through flow control valve
Fig. 19
Nominal operating voltage DC
[V]
24
Permissible voltage fluctuation
[%]
±10
Max. switching frequency
[Hz]
0.5
Switching time off
[ms]
40
Switching time on
[ms]
130
Duty cycle
[%]
100
Electrical connection
Sub-D, 9-pin (the product may only be operated with
the related multi-pin plug sockets NECA-S1G9-P9-MP…)
Protection class
IP65 with multi-pin plug socket NECA-...
Noise level
[dB(A)]
75 with silencer UOS-1
Information on material, housing
Die-cast aluminium
Information on material, seal
NBR
Max. current consumption
[A]
0.12
1)
Protection against electric shock
(protection against direct and indirect
contact as per EN 60204-1/IEC 204)
By means of PELV power supply unit
Switching position display
LED and potential-free contact
Semiconductor relay (signal contact)
–
Max. voltage
–
Max. continuous current
–
Max. resistance in the
switched-on status
–
Max. leakage current in the
switched-off status
[V]
[A]
[Ω]
[μA]
60
0.12
25 (typ. 18)
1
Min. pause after exhausting
[s]
1
Protection class
III
Fire protection classification to UL94
V0-V2
1)
During the switch on process, an increased starting current takes place short-term.
Tab. 9
General data