HSW−...−AP/A S
Festo HSW−...−AP/AS 0812b English
50
3. During the test run check:
that the proximity switches are functioning correctly
that the work load is held safely
the positioning time as a factor of the work load
the adjustment of the end positions.
4. When adjusting the end positions, observe the instructions in the chapter
Fitting".
Wa
rnin
g
Sudden movements of the actuators when they are under pressure during the
setting of the link angle can cause injuries, and loose link parts can damage the
HSW
S
Exhaust the drive before you loosen the fastening screws of the link parts.
After setting the link angle:
S
Make sure that the fastening screws of the link parts are screwed tight. In
this way you will avoid injury to human beings and damage to the device
(tightening torque: see Mechanical installation").
5. Open up the one−way flow control valves slowly again until the desired
positioning speed is reached.
6. Make sure that the pulse time does not drop below the minimum permitted
time.
D
e
f
inition
Pulse time t
t
= positioning time t + dwell time t
e
t:
Time which the HSW requires in order to move from the receive position
to the release position and back (for permissible values see chapter
Characteristic curves").
t
e
: Time during which the HSW remains in the receive position and release
position.
Содержание HSW-10-AP
Страница 183: ...HSW AP AS Festo HSW AP AS 0812b 183 ...