26
Festo — EXCT — 2022-03a
Assembly
5. Position the slot nuts in the slots according to the prepared drilled holes in the mounting surface.
When mounting on the profile backwall
–
Number of slots: 2x
–
Total number of slot nuts required:
–
2 mounting positions: 8x
–
3 mounting positions: 12x
When mounting on the bottom of the profile
–
Number of slots:
–
EXCT-15: 1x
–
EXCT-30/-100: 2x
–
Total number of slot nuts required:
–
2 mounting positions:
EXCT-15: 4x
EXCT-30/-100: 8x
–
3 mounting positions:
EXCT-15: 6x
EXCT-30/-100: 12x
6. Place the product on the mounting surface.
When mounting on the profile backwall
–
With suitable lifting equipment on the left drive housings or with the help of additional persons.
When mounting on the bottom of the profile
–
With suitable lifting equipment on the transport mounts of the mounting kits.
7. Select suitable M6 screws for mounting in the slot nuts.
• Select screws suitable for the installation situation.
• Use screws with a strength class of at least 8.8.
• Select the length of the screws according to the screw-in depth in the profile and the thickness
of the mounting surface.