10
Maintenance
10.1
Cleaning
–
If the piston rod is dirty, clean it with a clean, soft and lint-free cloth without
cleaning agents and then apply the lubricant thinly to the piston rod.
–
Clean the other product components with a clean, soft cloth and non-abrasive
cleaning agents.
10.2
Lubrication
Lubrication interval and accessories
Lubrication
Piston rod
Lubrication interval
If required, e.g. if the grease layer is insufficient.
Accessories
Lubrication point
Surface
Lubricant
ELKALUB VP 922, ChemieTechnik, Vöhringen
Tab. 13: Overview of lubrication intervals and accessories
11
Malfunctions
Acknowledge error
With error acknowledgment, active error messages are deleted from the diag-
nostic memory if the cause of the error was remedied before acknowledgment.
Errors can be acknowledged via the following interfaces:
–
Restart:
–
Logic voltage L
+
, Power OFF/ON [Logic, Pin 1]
–
HMI:
–
Press and hold
for 3 s
–
DIO, digital inputs:
–
DI1 "Mov
In
" and DI2 "Mov
Out
" = 1 [Logic, Pin 5/6]
–
IO-Link, device data:
–
0x0107.0 Quit Error = true
–
IO-Link, process data:
–
0x0029.3 Quit Error = true
–
0x0029.1 and 0x0029.2 = true, 0x0029.5 = any
Diagnostic messages and fault clearance
"Information, Warnings and Errors" diagnostic messages are displayed by the
C/Q LED and menu and parameters LED displays.
Errors are reported to the controller as follows:
–
DIO operation: output signals DO1 and DO2 = 1 [Logic, Pin 2/3]
–
IO-Link operation: ProcessDataInput state "In" (0x0028.1) and state "Out"
(0x0028.2) = true
The first error that occurred is always displayed.
Fig. 9: Display of diagnostic messages (example)
Error
code
Description
LED
LED displays
Event
code
hex
(dec)
C/Q
Menu
Parameter
(IO-
Link)
Warning
z
Warnings
1)
yellow
light
z
0x...
Errors
z
Common device error or
unlisted errors
red light
…
0x100
0
Remedy
–
Contact Festo
0x000F
(15)
I
2
t monitoring output stage
error limit
0x180
5
Remedy
–
0x0016
(22)
Undervoltage in logic supply
24 V
2)
0x180
4
Remedy
–
Check logic voltage supply
0x0017
(23)
Overvoltage in logic supply
24 V
0x180
3
Remedy
–
Check logic voltage supply
Error
code
Description
LED
LED displays
Event
code
hex
(dec)
C/Q
Menu
Parameter
(IO-
Link)
0x001F
(31)
Undervoltage in intermediate
circuit
0x180
6
Remedy
–
Check the load voltage
supply
–
Check power socket for
contamination
0x0026
(38)
Undervoltage in load supply
24 V
0x180
2
Remedy
–
Check the load voltage
supply
–
Check power socket for
contamination
0x0027
(39)
Overvoltage load supply 24 V
0x180
1
Remedy
–
Check the load voltage
supply
0x0031
(49)
Temperature in device too
low
0x400
0
Remedy
–
Check ambient conditions
0x0033
(51)
Temperature in device too
high
Remedy
–
Check ambient conditions
–
Check installation condi-
tions
0x012F
(303)
IO-Link connection inter-
rupted
IO-Link connection inter-
rupted
z
Remedy
–
Check power supply
–
Check IO-Link master
1) Additional information
è
Instruction manual for integrated drive EMCS-ST
2) This error can only be acknowledged by a restart.
Tab. 14: "Information, Warnings and Errors" diagnostic messages
11.1
Fault clearance
WARNING
Unexpected movement of components.
Injury due to impacts or crushing.
• Before working on the product, switch off the control and secure it to prevent it
from being switched back on accidentally.
WARNING
Risk of injury due to unexpected movement of components.
• Protect the positioning range from unwanted intervention.
• Keep foreign objects out of the positioning range.
• Perform commissioning with low dynamic response.
Fault description
Cause
Remedy
Loud running noises
or vibrations or rough
running of the cylinder
Torsional stresses
–
Install the cylinder free of tension. Make
sure that the contact surface is flat
–
Change the layout of the attachment compo-
nent (e.g. payload).
–
Align cylinder and attached guide element
parallel to each other.
–
Use external guide.
Resonant vibration of
the cylinder
Change the travel velocity.
Toothed belt wear
–
Contact local Festo Service.
–
Replace cylinder
Insufficient lubrication
of the piston rod
Lubricate the piston rod
lubrication intervals and accessories.
Vibration at the piston
rod
Operation at the reso-
nance point of the cyl-
inder
–
Change the travel velocity.
–
Change the payload geometry.
Piston rod does not
move
Drive pinion slips
–
Contact local Festo Service.
–
Replace cylinder
Loads too high
Reduce forces and torques. Consider dynamics.
Toothed belt ripped
–
Contact local Festo Service.
–
Replace cylinder