Assembly

WARNING

Risk of injury due to unexpected movement of components.
The drive can move freely in the voltage-free state. This can cause unexpected
movements of the connected mechanics and crush parts of the body.
• Bring moving parts of the mechanical system into a safe position.

Mount product 

è

 "Mini slide EGSC" instruction

manual 

è

  www.festo.com/sp.

7

Installation

WARNING

Risk of injury due to electric shock.
• For the electrical power supply with extra-low voltages, use only PELV circuits

that guarantee a reinforced isolation from the mains network.

• Observe IEC 60204-1/EN 60204-1.

Damage to the device due to non-approved potentials at the pins
• Power connection:

• Do not connect pin 3

• Logic connection:

• EMCS-ST is not hot-pluggable. Only after connection of the reference poten-

tials GND/L– [Pin 4/8] can 24 V levels be applied to digital outputs DO1/DO2
[Pin 2/3] or the IO-Link communication signal C/Q [Pin 3].

• The DO1/DO2 [Pin 2/3] digital outputs and the IO-Link C/Q [Pin 3] communi-

cation signal must be disconnected 100 ms before the power supply connec-
tions GND/L– [Pin 4/8] and 24 V DC/L + [Pin 1], e.g. by the interposition of
relay contacts.

• GND and L– connections:

• The Power, GND [Pin 2] and Logic, GND/L– [Pin 4/8] connections must have

the same potential.

1. Connect cables to the [Logic] and [Power] connections of the integrated drive

EMCS-ST.

2. Connect cables to the controller or IO-Link master and to the PELV fixed power

supply units.

Wiring diagram: DIO operation (digital I/O)

In NPN mode defined levels must be applied to the DI1/DI2 digital inputs of the
EMCS, e.g. by controller outputs with pull-up resistors (4.3 k

W

 recommended).

1

2

3

4

Fig. 5: Wiring diagram: DIO operation (digital I/O)

1

PELV fixed power supply for the
load voltage supply

2

PELV fixed power supply for the
logic power supply

3

Integrated drive EMCS-ST

4

Higher-level controller with dig-
ital I/O

Status and control signals
The following table shows the status and control signals and the electrical levels
of the digital inputs and outputs as a function of the "PNP/NPN" version of the
integrated drive.

Status and control
signal

Electrical levels
PNP, positive logic

NPN, negative logic

0

Low level (0 V)

High level (24 V)

1

High level (24 V)

Low level (0 V)

Tab. 2: Overview of status and control signals as a function of electrical levels

Wiring diagram: IO-Link operation

Current consumption of IO-Link power supply [Logic]
An input current at pin 1 (L+) of 100 ... 150 mA is required for operation.

Connecting IO-Link directly to the master

1

2

3

Fig.6

1

PELV fixed power supply for the
load voltage supply

2

Integrated drive EMCS-ST

3

IO-Link master with IO-Link inter-
face, port class A

Connecting IO-Link to the master via the NEFC adapter

Adapter NEFC up to production date 2021
NEFC adapters up to production date 2021 can only be used for IO-Link masters
with port class A.

1

2

3

4

Fig. 7: Wiring diagram: IO-Link operation with adapter, example of port class A

1

PELV fixed power supply for the
load voltage supply

2

Integrated drive EMCS-ST

3

IO-Link master with IO-Link inter-
face, port class A and B

4

Adapter NEFC

Core colours of Festo cables:
BK = black, BN = brown, BU = blue, GN = green, GY = grey, PK = pink,
WH = white, YE = yellow

8

Commissioning

WARNING

Risk of injury due to unexpected movement of components.
• Protect the positioning range from unwanted intervention.
• Keep foreign objects out of the positioning range.
• Perform commissioning with low dynamic response.

WARNING

Severe, irreversible injuries from accidental movements of the connected
actuator technology.
Unintentional movements of the connected actuator technology can result from
exchanging the connecting cables of a servo drive or between servo drives.
• Before commissioning: All cables must be correctly assigned and connected.

Содержание EGSS-BS

Страница 1: ... personnel have knowledge and experience in dealing with electric drive systems 3 Additional information Contact the regional Festo contact if you have technical problems è www festo com Accessories and spare parts è www festo com catalogue 4 Product overview 4 1 Scope of delivery The following components are included in the scope of delivery Mini slide unit EGSS Instruction manual for the mini sl...

Страница 2: ...he logic power supply 3 Integrated drive EMCS ST 4 Higher level controller with dig ital I O Status and control signals The following table shows the status and control signals and the electrical levels of the digital inputs and outputs as a function of the PNP NPN version of the integrated drive Status and control signal Electrical levels PNP positive logic NPN negative logic 0 Low level 0 V High...

Страница 3: ...erence end position Ref from the IO Link device data 0x0103 0 reference and start the homing with end position detection 0x0104 0 Execute Reference Movement only required if the reference end position Ref is different from the factory setting or if the useful range has been changed The drive system is referenced after a successful homing Homing sets the PosImp intermediate position and the PosStar...

Страница 4: ...tartRef PosAct è LimIn è LimOut press Run Start Press movement Start Stop and save Start Press Position PosStart Press Save press Execute demo run Start Stop Lock pushbutton actuators Lock HMI press and hold for 3 s or no push button actuator input for 15 s To acknowledge an error press and hold for 3 s Reset to factory settings press and simultaneously for 10 s and then carry out a Power OFF ON o...

Страница 5: ...y Speed Out 0x0101 0 Speed Out1 Velocity Speed In 0x0100 0 Speed In1 Force Torque 0x0102 0 Force1 2 Start Press Position PosStart Press 0x0105 0 Position Start Press mm 2 3 4 End position LimOut 0x0106 0 end position Out mm 4 Intermediate position PosImp 0x0108 0 Intermediate Position mm 3 4 Control point to point operation via digital inputs Positioning task Control signals MovIn DI1 Logic Pin 5 ...

Страница 6: ...too high 0x400 0 Remedy Check ambient conditions Check installation condi tions 0x012F 303 IO Link connection inter rupted IO Link connection inter rupted z Remedy Check power supply Check IO Link master 1 Additional information è Instruction manual for integrated drive EMCS ST 2 This error can only be acknowledged by a restart Tab 7 Information Warnings and Errors diagnostic messages 10 1 Repair ...

Страница 7: ... 24 Logic current consumption logic pin 1 mA DIO operation 100 300 IO Link operation 100 150 Load current consumption power pin 1 A 3 3 5 3 IO Link port class A IO Link protocol version Device V 1 1 1 Maximum value for Speed In Speed Out at level 10 2 Unchangeable parameter 3 Maximum value for Force at level 10 4 Force is controlled and evaluated by closed loop control of the motor current Dependi...

Отзывы: