DRRD-12 ... 63
22
Festo – DRRD-12 ... 63-Z6 – 1310b English
5.2
Pneumatic installation
•
If necessary, remove the covers in the pneu-
matic ports.
To adjust the swivel speed:
•
Use the GRLA one-way flow control valves.
These are screwed directly into the com-
pressed air supply ports.
Fig. 5
For vertical installation and eccentric loads:
•
Use the controlled check valve HGL or a compressed air spacer compensation reservoir VZS.
In this way you can prevent the effective load from sliding down suddenly if there is a sudden pres-
sure drop.
5.3
Electrical installation
Note
Multiple switching cycles of cylinder switches are possible, dependent on the design.
•
Make sure the cylinder switches are always set to the first switching point.
To do this, push the cylinder switch (A) in from the slot end where the piston to be
sensed is located until the first switching occurs.
•
Place the cylinder switches for sensing the end
positions into the slots
9
.
Sensing can be conducted with inductive prox-
imity sensors with the help of the external
sensing kit (
10 Accessories).
9
Fig. 6
(A)
9
Содержание DRRD-35
Страница 75: ...DRRD 12 63 Festo DRRD 12 63 Z6 1310b 75 3 12 20 10 12 HEL...
Страница 78: ...DRRD 12 63 78 Festo DRRD 12 63 Z6 1310b 5 2 GRLA Fig 5 HGL VZS 5 3 A 9 10 9 Fig 6 A 9...
Страница 79: ...DRRD 12 63 Festo DRRD 12 63 Z6 1310b 79 6 DRRD DRRD DRRD Y12 6 1 1 A 2 A Fig 7 Tab 4 3 DRRD 4 Fig 8...
Страница 85: ...DRRD 12 63 Festo DRRD 12 63 Z6 1310b 85 10 www festo com catalogue 11 DRRD Festo 10 9 Tab 8...
Страница 87: ...DRRD 12 63 Festo DRRD 12 63 Z6 1310b 87...