DNCE−...−LAS
Festo DNCE−...−LAS 1003b English
39
Malfunction
Re
m
edy
Possible cause
Squeaking noises or
vibrations
DNCE−LAS installed distorted
Rectify distortion
vibrations
No lubrication
Send DNCE−LAS to our repair
service
Working load too big
Observe permissible values as
per diagram in chapter
Speed too high
per diagram in chapter
Characteristic curves"
Incorrect parameterizing
Check parameters in the
SFC−LACI controller
Temperature increase due to
loading in continuous
operation
Repeat test run under
continuous operating
conditions
Electric cylinder not
reacting
Temperature monitoring
active
Observe permissible loading
values (take into account
temperature fluctuations
during course of year)
Incorrect parameterizing
Check parameters in the
SFC LACI controller
Mechanical structure not
stable
SFC−LACI controller
Warning in the
controller during
homing run:
Index/pulse warning
Position of the reference
switch critical
Move reference switch:
See documentation on the
controller SFC−LACI
Contact our repair service
Fig.12