DNCE−...−LAS
Festo DNCE−...−LAS 1003b English
31
Pin
Pin allocation
Function
Designation
Cable colour
1
n.c.
reserved
2
n.c.
reserved
3
4
5
6
3
black
Temp1
Temperature
sensor
1)
1
2
3
4
4
black
Temp1 GND
GND temperature
sensor
1)
5
blue
Ref+
Reference switch +
6
brown
Ref
Reference switch
Sensor plug, yellow
1
green
SLO+
Data output +
2)
2
yellow
SLO
Data output
2)
3
4
5
6
3
black
GND
GND measuring
system
1
2
3
4
4
brown
VCC
VCC measuring
system (+5VDC)
5
red
MA
Clock input
2)
6
orange
MA+
Clock input +
2)
Encoder plug, red
1)
A temperature sensor of type KTY11−5 from Infineon is used in the DNCE. The manu−
facturer’s characteristic curves and technical data can be found in the Internet.
2)
BiSS/ physical protocol RS485/422
Fig.7
BiSS interface measuring system
The BiSS interface is a 2−wire interface for interference−immune sensor connection.
In contrast to the SSI interface, data transmission is bidirectional, i.e. data can
also be written to the sensor, for example for parameterisation.
Data transmission takes place over a pulse wire and a data wire operated by the
sensor for serial transmission. Writing data to the slave is done via pulse−width mo
dulation of the clock in accordance with the BiSS B mode" protocol specification
http://www.biss−ic.de/files/BiSS_b3ds.pdf; a directional switch of the data trans
mission line does not take place. Pulse and data are transmitted in RS485 technology,
that is, a signal is not inverted and sent inverted and output at the receiver as a differ
Содержание DNCE-***-LAS
Страница 129: ...DNCE LAS Festo DNCE LAS 1003b 129...