26 / 46
Festo 7DHTGb_en
• Loosen the blanking plugs in the stop plate and unscrew them.
• Remove the O-rings from the housing.
• Pull the spacing bolt out of the housing.
• Loosen the four socket head screws in the flange on the underside of the
housing and unscrew them.
• Place the housing on two suitable supports so that there is a clearance of at
least 15 mm for driving out the flange.
min. 15 mm