Festo CPV10/14-ASI-8E6A 2018-11b English
5
3
Installation instructions
3.1 AS-Interface Addresses
Before connecting to the AS-Interface bus: assign an un
used address to each slave.
Please note
‒ The valve terminal type CPV..-GE-ASI-8E8A-Z contains
2 AS-Interface slaves. The valve terminal behaves on
the AS-Interface bus like two individual valve ter
minals each with 4 inputs and 3 outputs (valve sole
noid coils).
Assignment of the inputs and outputs (valves):
– Slave 1: Inputs I0...I3; outputs O0...O2
– Slave 2: Inputs I4...I7; outputs O4...O6.
‒ Automatic addressing with the function “Automatic
address assignment” of the master is not possible.
‒ It is not necessary to parametrize the AS-Interface
slave.
Address assignment
The assignment of the data bits to the inputs and outputs
of the slave shows the following figure:
Slave 1: IO code 7
H
Slave 2: IO code 7
H
D0
D1
D2
D3
I/O
I/O
I/O
I/O
I0
I1
I2
I3
O0
O1
O2
–
Inputs:
Outputs:
Data bits:
D0
D1
D2
D3
I/O
I/O
I/O
I/O
I4
I5
I6
I7
O4
O5
O6
–
E/A =
b
i directional (B)
The address mapping depends on the configuration of the
master.