CPS Gate
© Festo Didactic 8075265
45
5
Work and safety instructions
General
•
Apprentices should only work with the circuits under the supervision of an instructor.
•
Observe the specifications included in the technical data for the individual components, and in
particular all safety instructions!
•
Malfunctions which may impair safety must not be generated.
•
Wear personal safety equipment (safety glasses, safety shoes) when working on circuits.
Electrical safety
•
Risk of death in case of interrupted protective earth conductor!
–
The protective earth conductor (yellow-green) must not be interrupted, either inside or outside of
the device.
–
The insulation of the protective conductor must never be damaged or removed.
•
Risk of death from connecting power supply units in series!
Contact voltages of greater than 25 V ac or 60 V dc are not permissible.
Coming into contact with voltages of greater than 50 V ac or 120 V dc may be fatal.
–
Do not connect voltage sources in series.
•
Risk of death due to electric shock!
Protect the outputs of the power supply units (output sockets/terminals) and cables connected to them
from direct contact.
–
Use only cables with adequate insulation and electric strength.
–
Use safety sockets with fully shrouded contact points.
•
Disconnect from all sources of electrical power!
–
Switch off the power supply before working on the circuit.
–
Please note that electrical energy may be stored in individual components. Further information on
this issue is available in the data sheets and operating instructions included with the components.
–
Caution!
Capacitors inside the device may still be charged even after being disconnected from all sources of
voltage.
•
Establishing and interrupting electrical connections
–
Electrical connections may only be established in the absence of voltage.
–
Electrical connections may only be interrupted in the absence of voltage.
Содержание CPS-Gate