2.3.3 Connecting the load voltage
WARNING
Use only power units which guarantee reliable
isolation of the operating voltages as per IEC 742 /
EN 60742 / VDE 0551 with at least 4 kV isolation
resistance (protected extra low voltage, PELV).
Switch power packs are permitted if they guarantee
reliable isolation in accordance with EN 60950/
VDE 0805.
By using PELV power units, protection against electric
shock (protection against direct and indirect contact) in
accordance with EN 60204-1 / IEC 204 is guaranteed
on Festo valve terminals. Safety transformers with the
adjacent designation must be used for supplying PELV
networks. The valve terminals must be earthed in order
to ensure their function (e.g. EMC).
The connected actuators are supplied with + 24 V DC
via the load voltage connection on the output module.
Use a cable with sufficiently large cross-sectional area
for the operating voltage.
2. Output module type CP-A08...-M12-...
2-14
CP-A08...-M12 9901b
Содержание CP-A08 Series
Страница 1: ...Compact Performance CP Modules Electronics Input modules type CP E16 M Output modules type CP A08 M12...
Страница 3: ...Part no 165 225 Title Manual Designation P BE CPEA GB II CP EA 9901b...
Страница 11: ...X CP EA 9901b...
Страница 12: ...Chapter 1 Input module type CP E16 M 1 Input module type CP E16 M CP E16 M 9901b 1 1...
Страница 39: ...1 Input module type CP E16 M 1 28 CP E16 M 9901b...
Страница 40: ...Chapter 2 Output module type CP A08 M12 2 Output module type CP A08 M12 CP A08 M12 9901b 2 1...
Страница 61: ...2 Output module type CP A08 M12 2 22 CP A08 M12 9901b...
Страница 62: ...Appendix A Index A Index CP EA 9901b A 1...
Страница 63: ...A Index A 2 CP EA 9901b...
Страница 67: ...A Index A 6 CP EA 9901b...