![Festo CMMP-AS Скачать руководство пользователя страница 78](http://html1.mh-extra.com/html/festo/cmmp-as/cmmp-as_manual_2283115078.webp)
6. Control via FHPP
78
Festo.P.BE-CMMP-CAM-SW-EN en 1105a
6.8
Description of the parameters (PNU 700 … 720)
Allocation
Name
Access
PNU
IND
Type
Cam disc
Cam disc number
rw
700
--
uint8
Master start position virtual master
rw
701
--
int32
Synchronisation
(input X10)
Input configuration
rw
710
--
uint32
Gear ratio
rw
711
1..2
uint32
Encoder
emulation
(output X11)
Output configuration
rw
720
--
uint32
FHPP
700
--
Optional
uint8
Name DE/EN
Kurvenscheibennummer
CamID (cam disc number)
Description
The cam disc is selected with this parameter.
Value range 1 ... 16
Read/write
rw
FHPP
701
--
Optional
int32
Name DE/EN
Masterstartposition
Description
For virtual master, establishes the start position of the master.
Read/write
rw