![Festo CMMP-AS Скачать руководство пользователя страница 64](http://html1.mh-extra.com/html/festo/cmmp-as/cmmp-as_manual_2283115064.webp)
5. Commissioning examples
64
Festo.P.BE-CMMP-CAM-SW-EN en 1105a
Step 3
On the “Cam Disc” page in the “Master” tab: Activate the “Virtual Master” option.
If necessary: Activate modulo positioning and specify the area limits.
The modulo function is described in section 4.6.
Steps 4 … 6
Steps 4 to 6 correspond to those for parameter setting in section 5.2 Example 1: Physical
master with a slave.
Create a curve with cams as described there.
Step 7
Establish an online connection and execute a download to the controller. Using the “Store”
button, store the project in the device and restart the controller: “Component/Restart
Controller” (especially for CANopen applications, since a CAN reset is usually sent here
before a start).
Then set the FCT device control (“FCT” and “Enable”).
Execute homing (if necessary).