![Festo CMMP-AS Скачать руководство пользователя страница 76](http://html1.mh-extra.com/html/festo/cmmp-as/cmmp-as_manual_2283115076.webp)
6. Control via FHPP
76
Festo.P.BE-CMMP-CAM-SW-EN en 1105a
6.7
Record selection
6.7.1
Record control byte 1 (RCB1, PNU 401)
The record control byte 1 (RCB1) is transferred into PNU 401. Every positioning record has
its own subindex: The record control byte of positioning record 1 is in PNU 401/01, that of
positioning record 2 in PNU 401/02, etc.
Bit 0
ABS
= 0: Setpoint value is absolute
= 1: Setpoint value is relative to the last setpoint/switch-further value
Bit
1..2
COM1
COM2
= 00: Position control
= 01: Force control/torque control
= 10: Rotational speed/velocity control
= 11: Reserved
Bit
3..4
FNUM
B3 – B4 are interpreted together as a number.
Value
Significance
0
Reserved
1
Synchronisation on external input
2
Synchronisation on external input with cam disc function
3
Synchronisation on virtual master with cam disc function
Bit
5..6
FGRP
B5 – B6 are interpreted together as a number.
Value
Significance
0
Synchronisation with/without cam disc
1
Reserved
2
Reserved
3
Reserved
Bit 7
FUNC
= 0: Normal job
= 1: Function / execute macro ( FGRP / FNUM )
For FNUM=1 or 2, bit 0 … 2 are without significance (always position control).
For FNUM =3, bit 0 applies for the virtual master, bit 1 and 2 are without significance