4
Commissioning
Festo – GDCP-CMMP-AS-M0-S1-EN – 1412a – English
27
4.2
Support by FCT
No parametrisation is required for the safety function integrated in the motor controller.
4.2.1
Status display of the safety function
The status of the safety function is displayed in the FCT,
è
Properties
Display
Status
Status:
Status display
Green
Normal mode (no STO requested)
Yellow
STO requested and achieved
Red
Safety circuit error
Input X40.STOA:
Display of the input status
Grey
Safety function requested, STO-A = Low
Green
No safety function requested, STO-A = High
Input X40.STOB:
Display of the input status
Grey
Safety function requested, STO-B = Low
Green
No safety function requested, STO-B = High
Output X40.C1/C2:
Display of the relay contact
Orange
Safety function active, relay contact closed
Grey
Safety function inactive, relay contact open
Tab. 4.1
Status of the safety function
4.2.2
Display log file of the motor controller
Error and status messages are logged in the permanent diagnostic memory of the CMMP-AS-...-M0 in a
non-volatile manner. You can read these messages under the online “Diagnostics” tab
è
Fig. 4.1
FCT-plug-in CMMP-AS: “Diagnostics” tab