Description of the safety function STO
20
Festo – GDCP-CMMP-AS-M0-S1-EN – 1412a – English
Time
Description
Value
T_K1
Delay between the switching of S1 and the closing
of the undelayed contact K1
è
Data sheet for the safety
switching device
T_K1_V
Delay between S1 and the opening of the relapse
delayed contact K1
Can be set on the safety
switching device
T_STO-A/B_OFF
STO-A/B – Switching time from High to Low
è
T_STO-A/B_ON
STO-A/B – Switching time from Low to High
è
T_DRIVE_V
Deceleration of the CMMP-AS-...-M0
0 … 10 ms
T_DIN5_SU
Time for which the DIN5 must be Low after
switching on STO-A/B again and status change of
the integrated protection circuit
20 ms
T_BRAKE_V_ON
Switch off delay of the holding brake
T_BRAKE_V_OFF
Switch on delay of the holding brake
1)
Physical delay until the brake closes.
2)
Minimum time: Physical time delay until the brake opens. This time can be parameterised in the controller via a larger value.
Tab. 2.5