9. Service functions and error messages
92
Festo P.BE-CMMP-AS-3A-HW-EN 0708NH
Error messages with a main index of 00 indicate information and not a run-time error. User
measures are not usually necessary. They only appear in the error buffer and are not
shown on the seven-segment display.
The meaning and the measures for the error messages are compiled in the table below:
Error message
Meaning of error message
Measures
Main index
Main
index
Sub-
index
00
0
Invalid error
Information: An invalid error entry (corrupted)
was found in the error buffer marked with this
error number.
No measures required.
1
Invalid error discovered and
corrected
Information: An invalid error entry (corrupted) was
found in the error buffer and corrected.
The debug information contains the original error
number.
No measures required.
2
Error deleted
Information: Active errors were quit
No measures required.
4
Serial number / Device type
(module exchange)
Information: An exchangeable error store (service
module) was plugged into another device.
No measures required.
01
0
Stack overflow
Wrong firmware?
Reload standard firmware if necessary.
Contact Technical Support.
02
0
Undervoltage at intermediate
circuit
Error priority set too high?
Check the intermediate circuit voltage (measure).
03
0
Analogue motor overtempera-
ture
Motor too hot? Check the parameterising (current
controller, current limit values)
Suitable sensor?
Defective sensor?
If error also exists with a bridged sensor: Device de-
fective.
1
Digital motor overtemperature
04
0
Power end stage overtempera-
ture
Temperature display plausible?
Check the mounting conditions, fan filters dirty?
Device fan defective?
1
Intermediate circuit overtem-
perature
05
0
Internal voltage 1 failed
Error cannot be rectified independently.
The servo positioning controller must be sent to your
local sales partner.
1
Internal voltage 2 failed
2
Driver supply failure
3
Digital I/O undervoltage
Check outputs for short-circuit or check specified
loading. If necessary, contact Technical Support.
4
Digital I/O overcurrent
Содержание CMMP-AS-C2-3A
Страница 2: ......