A
Technical appendix
Festo – GDCP-CMMS-AS-G2-S1-EN – 1306NH – English
39
Auxiliary supply 24 V, 0 V – output [X3.1, X3.3]
Feature
Logic supply voltage routed out of the motor controller (fed
in at [X9], not additionally filtered or stabilised).
Nominal voltage
[V]
24
Nominal current
[mA]
100 (not short-circuit proof )
Voltage drop
[V]
≤
1 (at nominal current)
Tab. A.8
Technical data: electrical data of the auxiliary supply output [X3]
Cabling [X3]
Max. cable length
[m]
30
Screening
When wiring outside the control cabinet, use screened
cable. Guide screening into the control cabinet / attach to
the side of the control cabinet.
Cable cross section (flexible conductors, wire end sleeve with insulating collar)
One conductor
[mm²]
0.25 … 0.5
Two conductors
[mm²]
2 x 0.25 (with twin wire end sleeves)
Tightening torque M2
[Nm]
0.22 … 0.25
Tab. A.9
Technical data: cabling at [X3]