2
Description of the safety function STO
Festo – GDCP-CMMS-AS-G2-S1-EN – 1306NH – English
25
2.4.4
Timing diagram SS1
Controller enable
DIN5 [X1.9]
Output stage
enable DIN4
[X1.21]
Actual speed
value
Output stage
active
Open holding
brake BR+ [X6.2]
Holding brake
open (mechanical)
t1
7-segment display
t2
t
STO
Acknowledgment
contact NC1/NC2
[X3.5/6]
Driver supply relay
Rel [X3.2]
t6
Safe Torque Off
t7
‘H’
t6
t11
t9
t8
t13
t3
t4
t5
t7
t12
Open
Closed
Open
t10
t1
≤
5 ms
t2
= 0 ms…10 s (dependent on the actual speed
value and quick-stop delay parameterised
with FCT)
t3
= 0…6553 ms (switch-off delay brake
parameterised with FCT)
t4
≤
5 ms
t5
time delay PNOZ (
>
t1 + t2 + t3 + t4)
t
STO
≤
12 ms
t6
≤
30 ms
t7
≤
720 ms
t8
≤
20 ms
t9
any
t10
>
2.5 ms
t11
≤
5 ms (For control via the fieldbus,
controller enable via fieldbus is also required
beforehand)
t12 = 50…500 ms (dependent on the brake used)
t13 = 0…6553 ms (with FCT parameterised
switch-on delay brake)
Fig. 2.6
Timing diagram SS1
Содержание 572986
Страница 1: ...Description STO safety function 8026151 1306NH Motor controller CMMS AS G2 STO...
Страница 41: ......