4
0
The guarantee will become void if above instructions about cooling mechanism
is not conformed.
In the cooling cabinet, ice formed on the
expansion coil melts automatically and
the resulting water is conducted to the
evaporation trough in the compressor
area, from which it evaporates auto-
matically.
AIR CIRCULATION
Faultless functioning of the cooling
mechanism presupposes that the air
circulation outside and also inside the
appliance is good (see drawings below).
The air inlet of bottom must not be cove-
red.
Above the appliance must be left at least
40mm blank (dwg 2).
Other alternative is to leave at least 80mm
blank also above and behind the fixture
above the cooling cabinet (dwg 1).
FUNCTIONING OF THE COOLING
MECHANISM
The cooling mechanism consists of the
compressor, the condenser and the ex-
pansion coil; these form a closed circuit
in which the compressor circulates the
coolant.
In the expansion coil, the refrigerant is va-
porized and binds heat to itself, cooling
the cabinet. The heat bound to the refrige-
rant goes out via the condenser into the
surrounding air space.
FIXTURE
FIXTURE
Compressor
Condenser
Expansion
coil
Functional description
Drawing 1
Drawing 2