MACHINE AND
ACCESSORIES
Page 15 / 26
Turn the guides aligning the reference mark
on the support with the graduated scale on
the machine frame (Figure 7), and then
tighten the screws again.
Figure 7 Setting chamfer angle.
To adjust the chamfer depth, loosen the two
screws (one on each side) that attach the
motor/spindle unit to the machine frame.
Figure 8 Loosening the screws.
Unlock the safety nut under the knob with an Allen key.
Turn the knob located at the upper part of the machine so as to align the reference
mark on the frame with the graduated scale applied in the vicinity of the screw (see
Figure 9). Then tighten the screws and the lock nut again.
Figure 9 Adjustment depth.
Note:
the graduated scales on the machine are merely indicative, whenever a strict
adjustment of the chamfer angle and/or depth is required it is necessary to use appropriate
measuring instruments.