13
TECHNICAL DATA AND PERFORMANCES
Frame
1
2
Model
19 .1
22 .1
26 .1
30 .1
35 .1
40 .1
U.M.
Power supply
400 - 3N - 50
400 - 3N - 50
400 - 3N - 50
400 - 3N - 50
400 - 3N - 50
400 - 3N - 50
V-ph-Hz
NOMINAL performances - Low noise setting up (AS) - Standard plants
NOMINAL performances - Low noise setting up (AS) - Standard plants - EUROVENT certified data
IR
Cooling A35W7
( source : air in 35°C d.b. / plant : water in 12°C out 7°C )
Cooling capacity
19,1
21,2
24,8
29,6
34,2
38,6
kW
Power input
7,34
8,09
9,42
11,6
13,3
15,0
kW
EER
2,60
2,62
2,63
2,55
2,57
2,57
-
Water flow rate plant side
3295
3655
4273
5113
5903
6658
l/h
Pressure drops plant side
24
29
24
33
28
36
kPa
IP
Cooling A35W7
( source : air in 35°C d.b. / plant : water in 12°C out 7°C )
Cooling capacity
18,7
20,8
24,3
29,1
33,6
37,8
kW
Power input
7,27
8,00
9,33
11,4
13,1
14,9
kW
EER
2,57
2,60
2,60
2,55
2,56
2,54
-
Water flow rate plant side
3226
3586
4187
5010
5783
6520
l/h
Pressure drops plant side
23
28
23
32
27
34
kPa
Heating A7W45
( source : air in 7°C d.b. 6°C w.b. / plant : water in 40°C out 45°C )
Heating capacity
19,9
22,2
25,8
31,0
35,8
40,3
kW
Power input
6,22
6,85
7,98
9,88
11,3
12,8
kW
COP
3,20
3,24
3,23
3,14
3,17
3,15
-
Water flow rate plant side
3381
3773
4388
5259
6078
6847
l/h
Pressure drops plant side
25
30
25
35
30
37
kPa
Heating A2W45
( source : air in 2°C d.b. 1°C w.b. / plant : water in 40°C out 45°C )
Heating capacity
16,4
18,3
21,3
25,5
29,5
33,2
kW
Power input
6,13
6,74
7,87
9,73
11,1
12,6
kW
COP
2,68
2,72
2,71
2,62
2,66
2,63
-
Water flow rate plant side
2800
3107
3620
4337
5020
5651
l/h
Pressure drops plant side
17
21
17
24
21
26
kPa
Frame
1
2
Model
19 .1
22 .1
26 .1
30 .1
35 .1
40 .1
U.M.
Power supply
400 - 3N - 50
400 - 3N - 50
400 - 3N - 50
400 - 3N - 50
400 - 3N - 50
400 - 3N - 50
V-ph-Hz
IR
Cooling A35W7
( source : air in 35°C d.b. / plant : water in 12°C out 7°C )
Cooling capacity
19,2
21,3
24,9
29,8
34,4
38,8
kW
EER
2,64
2,67
2,67
2,61
2,63
2,62
-
Pressure drops plant side
24
29
24
33
28
35
kPa
ESEER
2,98
3,02
3,02
2,95
2,97
2,96
-
IP
Cooling A35W7
( source : air in 35°C d.b. / plant : water in 12°C out 7°C )
Cooling capacity
18,8
20,9
24,4
29,2
33,7
38,0
kW
EER
2,61
2,64
2,64
2,58
2,59
2,59
-
Pressure drops plant side
23
28
23
32
27
34
kPa
ESEER
2,95
2,98
2,98
2,92
2,93
2,93
-
Heating A7W45
(air 7 °C bs - 6 °C bu / water 40 - 45 °C )
Heating capacity
19,8
22,1
25,7
30,8
35,6
40,1
kW
COP
3,22
3,28
3,26
3,17
3,21
3,18
-
Pressure drops plant side
25
31
25
35
30
38
kPa
Data declared according to
EN 14511
. The values are referred to units without options and accessories.