4.4 Technical data table
Table 11- Technical data table
Data
Unit
BLUEHELIX TOP RRT 28 K 50
BLUEHELIX TOP RRT 34 K 50
PRODUCT IDENTIFICATION CODES
0T3T2AWA
0T3T3AWA
COUNTRIES OF DESTINATION
IT - ES - RO - PL - SK
GAS CATEGORY
(IT) - II2H3+ (ES - SK) - II2H3B/P (RO) - II2ELW3B/P
Max. heating capacity
kW
24.5
30.6
Q
Min. heating capacity
kW
2.9
2.9
Q
Max. heat output in heating (80/60°C)
kW
24.0
30.0
P
Min. heat output in heating (80/60°C)
kW
2.8
2.8
P
Max. heat output in heating (50/30°C)
kW
26.0
32.5
Min. heat output in heating (50/30°C)
kW
3.1
3.1
Max. heating capacity in DHW
kW
28.5
34.7
Min. heating capacity in DHW
kW
2.9
2.9
Max. heat output in DHW
kW
28.0
34.0
Min. heat output in DHW
kW
2.8.9
2.8
Efficiency Pmax (80-60°C)
%
98.1
97.9
Efficiency Pmin (80-60°C)
%
98.0
98.0
Efficiency Pmax (50-30°C)
%
106.1
106.1
Efficiency Pmin (50-30°C)
%
107.5
107.5
Efficiency 30%
%
109.7
109.5
Gas supply pressure G20
mbar
20
20
Max. gas flow G20
m
3
/h
3.02
3.67
Min. gas flow G20
m
3
/h
0.31
0.31
CO
2
- G20
%
9 ±0.8
9 ±0.8
Gas supply pressure G31
mbar
37
37
Max. gas flow G31
kg/h
2.21
2.70
Min. gas flow G31
kg/h
0.23
0.23
CO
2
- G31
%
10 ±0.8
10 ±0.8
NOx emissions class
-
6
6
NOx
Max. working pressure in heating
bar
3.0
3.0
PMS
Min. working pressure in heating
bar
0.8
0.8
Heating adjustment max. temperature
°C
95
95
tmax
Heating water content
liters
4.2
4.2
Heating expansion vessel capacity
liters
10
10
Heating expansion vessel precharge pressure
bar
0.8
0.8
Max. working pressure in DHW
bar
9.0
9.0
Min. working pressure in DHW
bar
0.3
0.3
Hot water tank capacity
Liters
40
40
DHW expansion vessel capacity
Liters
2
2
DHW flow 30°C
l/10 min
161
195
DHW flow 30°C
l/h
831
1005
Protection rating
IP
IPX4D
IPX4D
Power supply voltage
V/Hz
230V/50Hz
230V/50Hz
Electrical power input
W
82
99
Empty weight
kg
62
65
Type of unit
C13-C23-C33-C43-C53
C63-C83-B23-B33