Installation and maintenance manual
pag. 20 / 23
Parameter description
Code
U.M.
Min
Max
Default Notes
Anti-Legionella function set
H1
°C/°F
10.0
199.0
70.0
Duration of Anti-Legionella function
H3
min
0
240
2
Digital 1 input enabling
i0
----
0 2
2
0 = Input disabled
1 = Pressure input
2 = GREEN input
Type of digital 1 input contact
i1
----
0 1
0
0 = Active if contact is
closed
1 = Active if contact is
open
High/low pressure end compressor
protection
i2 min
0 120
0
Photovoltaic input enabling
i3
----
0 1
1
0 = Input disabled
1 = Input enabled
Type of photovoltaic input contact i4
----
0 1
0
0 = Active if contact
closed
1 = Active if contact
open
Number of digital input alarms per
equipment block
i8 ----
0 15
0
Time for digital input alarm counter reset
i9
min
1
999
240
Buzzer enabling u9
----
0 1
1
0 = Buzzer disabled
1 = Buzzer enabled
Switching on time for Monday Hd1
----
1 2
1
1 = HOn1-HOF1
2 = HOn2-HOF2
Switching on time for Tuesday Hd2
----
1 2
1
1 = HOn1-HOF1
2 = HOn2-HOF2
Switching on time for Wednesday Hd3
----
1 2
1
1 = HOn1-HOF1
2 = HOn2-HOF2
Switching on time for Thursday Hd4
----
1 2
1
1 = HOn1-HOF1
2 = HOn2-HOF2
Switching on time for Friday Hd5
----
1 2
1
1 = HOn1-HOF1
2 = HOn2-HOF2
Switching on time for Saturday
Hd6
----
1 2
2
1 = HOn1-HOF1
2 = HOn2-HOF2
Switching on time for Sunday Hd7
----
1 2
2
1 = HOn1-HOF1
2 = HOn2-HOF2
Time for first switch on timeslot
HOn1
----
00:00 23.59
--:--
--:-- = Function excluded
Time for first switch off timeslot
HOF1
----
00:00 23.59
--:--
--:-- = Function excluded
Time according to timeslot switch on
HOn2
----
00:00 23.59
--:--
--:-- = Function excluded
Time according to timeslot switch off
HOF2
----
00:00 23.59
--:--
--:-- = Function excluded
Equipment address
LA
----
1
247
247
Baud Rate Lb
----
0 3
2
0 = 2400
1 = 4800
2 = 9600