1. GENERAL 

 

 

Carefully read and follow the instructions contained in 
this instruction booklet.

 

 

After  boiler  installation,  inform  the  user  regarding  its 
operation  and  give  him  this  manual, which is an inte-
gral and essential part of the product and must be kept 
with  care for future reference.

 

 

Installation and maintenance must be carried out by pro-
fessionally  qualified  personnel,  in  compliance  with  the 
current regulations and according to the manufacturer's 
instructions.  Do  not  carry  out  any  operation  on  the 
sealed control parts.

 

 

Incorrect  installation  or  inadequate  maintenance  can 
result in damage or injury. The  manufacturer  declines 
any liability for damage due to errors in installation and 
use,  or failure to follow the instructions.

 

 

Before carrying out any cleaning or maintenance opera-
tion, disconnect the unit from  the electrical power sup-
ply using the switch and/or the special cut-off devices.

 

 

In case of a fault and/or poor operation, deactivate the 
unit  and  do  not  try  to  repair  it  or  directly  intervene. 
Contact  professionally  qualified  personnel.  Any  repair/
replacement of the products must only be carried out by 
qualified  personnel  using  original  replacement  parts. 
Failure to comply with the above could affect the safety 
of  the unit.

 

 

This  unit  must  only  be  used  for  its  intended  purpose. 
Any  other  use  is  deemed  improper  and  therefore      
hazardous.

 

 

The  packing  materials  are  potentially  hazardous  and 
must not be left within the  reach of children.

 

 

The unit must not be used by people (including children) 
with limited physical, sensory or mental abilities or with-
out experience and knowledge of it, unless instructed  or 
supervised  in  its  use  by  someone  responsible  for  their 
safety.

 

 

The unit and its accessories must be appropriately dis-
posed of, in compliance with  the current regulations.

 

 

The images given in this manual are a simplified repre-
sentation  of  the  product.  In  this  representation  there 
may be slight and insignificant  differences with respect 
to the product supplied.

 

HEALTH & SAFETY

 

 

The electricity at work regulations, 

1989

The manufacturer's notes  must NOT be taken, in any 
way, as overriding statutory  obligations.

 

 

IMPORTANT

.

 These appliances are CE certi

ed for     

safety  and performance.  It is, therefore, important 
that no external control devices, e.g. 

ue dampers,         

economisers  etc., are directly connected to these      
appliances unless covered by these Installation and 
servicing   Instructions or as otherwise recommended 
by 

Ferroli Ltd 

in writing.  If in doubt please enquire.

 

Any direct connection of a control device not      
approved by  

Ferroli Ltd could invalidate the       

certi

cation and the normal appliance warranty.  It 

could also infringe the Gas Safety Regulations and 
the above regulations.

 

Introduction

 

   

                                                                                   

Dear Customer,

                                                                   

Thank you for choosing the

 New Condens FS Series

, a 

floor-standing boiler featuring  advanced  design,  cutting-

edge  technology,  high  reliability  and  quality  construc-

tion.  Please read this manual carefully since it provides 

important information on safe installation, use and mainte-

nance.

   

New Condens FS Series 

is a high efficiency, 

low emissions 

premix condensing 

heat generator for 

heating, running on natural gas and equipped with a micro-

processor  control system.

                                                            

The 

boiler body 

consists of a sectional cast aluminium 

alloy heat exchanger  and  a 

woven mesh premix burn-

er 

in stainless steel, equipped with electronic ignition with 

ionisation flame  control, modulating speed fan and mod-

ulating gas valve. 

New Condens FS Series 

is a heat 

generator arranged to operate alone or in cascade.

 

 

Содержание 303: 304

Страница 1: ...NEW CONDENS FS 300 SERIES Cast Aluminium Floor Standing Condensing Boilers for Natural Gas INSTRUCTIONS FOR USE INSTALLATION AND MAINTENANCE Rev 00 12 2015 PB IB300 ...

Страница 2: ...lies with the following EU directives Gas Appliance Directive 2009 142 Efficiency Directive 92 42 Low Voltage Directive 2006 95 Electromagnetic Compatibility Directive 2004 108 EN President andLegalRepresentative NEW CONDENS FS 300 SERIES 0051 ...

Страница 3: ... appliance The installer must abide by the following instructions Read and follow the instructions given in the manuals provided with the appliance Install the appliance in compliance with prevailing legislation and standards Carry out initial commissioning and any checks necessary Explain the installation to the user If maintenance is necessary warn the user of the obligation to check the applian...

Страница 4: ...someone responsible for their safety The unit and its accessories must be appropriately dis posed of in compliance with the current regulations The images given in this manual are a simplified repre sentation of the product In this representation there may be slight and insignificant differences with respect to the product supplied HEALTH SAFETY The electricity at work regulations 1989 The manufac...

Страница 5: ...0 160 150 Structural Characteristics Water Contents l 6 5 8 5 10 5 12 5 14 5 Empty weight kg 107 133 164 196 226 Width mm 420 490 490 580 580 Height mm 1220 1220 1220 1240 1260 Depth mm 755 865 1130 1275 1415 Electrical Specifications Power supply voltage V Hz 230 50 Protection level IP 20 Power consumption W 160 190 260 260 320 Water and Gas Fittings Central heating flow outlet 1 1 1 1 1 Central ...

Страница 6: ...100 233 87 104 302 R 1 R 80 50 304 488 803 1078 934 380 941 111 281 97 156 394 R 1 R 100 80 305 488 1066 1078 949 394 932 120 284 96 160 374 R 1 R 1 110 80 306 583 1213 1138 945 385 963 127 305 97 183 385 R 1 R 1 125 115 307 583 1309 1138 956 396 945 133 311 110 175 433 R 1 R 1 160 115 ...

Страница 7: ...nt 600mm except access doors may be closer but not less than 200mm and 600mm must still be available for service across the width of the boiler Rear 1000mm or adequate space from the rear of the jacket to make the flue connections and access to the flue sample point drain connection flue and any safety or control devices Top 800mm Left side 800mm Right side 800mm Between boilers 200mm Recommended Min...

Страница 8: ...s in buildings BS 6880 1 1988 Code of practice for low temperature hot water heating systems of output greater than 45 kW Funda mental and design considerations BS 6880 2 1988 Selection of equipment BS 6880 3 1988 Installation commissioning and maintenance BS EN 13384 1 2015 Chimneys Thermal and fluid dynamic calculation methods Chimneys serving one heating appliance BS EN 13384 2 2015 Chimneys Th...

Страница 9: ... soundness and purged in accordance with the appropriate standards Gas Boosters A gas booster is required if the gas pressure available at the boiler is lower than that required by the boiler manufacturer to attain the flow rate for maximum burner input rating Location of the booster requires careful consideration but should preferably be closer to the burner rather than the gas meter Ventilation s...

Страница 10: ...om a clean source outside the boiler room building Where it is not possible to duct air from outside the boiler the air inlet guard MUST be used Material With no requirement for buoyancy to discharge flue products and with low flue gas temperatures single wall flues are suitable for most installations Care should still be taken to maintain compliance with building regulations and relevant standards T...

Страница 11: ...s a pump must be sup plied from the terminals inside the boiler Note for pumps requiring greater than 1 0 amp current they must be con nected via a relay When sizing pumps reference should be made to the Hydraulic Resistance Table on page 12 which show the boiler resistance against flow rates to achieve the required temperature differential Flow rates for common systems using either 11o C or 20o C ...

Страница 12: ...H value and the volume of top up water used It is most important that the correct concentration of the water treatment products is maintained in accordance with the manu facturers instructions If the boiler is installed in an existing system any unsuitable additives MUST be removed by thorough cleansing In hard water areas treatment to prevent lime scale may be necessary In this instance the use o...

Страница 13: ... not show safety valves wa ter flow switches etc necessary for the safe operation of the system Cold Feed Pipe Sizes Open Vent Pipe Sizes OPEN VENTED SYSTEM REQUIREMENTS Detail reference should be made to the appropriate standards listed on page 8 The information and guidance given below is not intended to override any requirements of the above publications or the requirements of the local authorit...

Страница 14: ...er is specified the flue manifold conden sate drain connection must also be connected in the same manner SEALED SYSTEM REQUIREMENTS Working pressure 6 bar maximum Particular reference should be made to BS 6644 and Guid ance note BG01 Automatically controlled steam and hot water boilers published by the Health and Safety Executive The information and guidance given below is not intended to override a...

Страница 15: ... should be 3 core PVC insulated cable NOT LESS than 0 75mm2 24 x 0 2 mm and to BS 6500 The fuse rating should be 7A Wiring external to the boiler MUST be in accordance with the current I E E BS7671 wiring Regulations and any local regu lations For Ireland reference should be made to the current ETCI rules for electrical installations Connection should be made in a way that allows complete isolatio...

Страница 16: ...16 Wiring diagram ...

Страница 17: ...17 Sensor locations ...

Страница 18: ... drain system and trap Ensure the water is circulating correctly between the boiler and the system Ensure the gas valve modulates correctly in heating and domestic hot water modes Put the boiler through several ignition sequences to ensure correct firing operation Using a combustion analyser connected to the boiler flue outlet check that the CO2 content in the fumes with the boiler operating at ma...

Страница 19: ...he units memory the information button will need to be pressed again until a percentage figure is shown on the screen Fig 2 The display now shows the boilers power output as a percentage Press the confirmation button once The figure will now flash intermittently Rotate the selection dial until the figure reads 100 Fig 3 Press the confirmation button once more to save this value To reduce the boile...

Страница 20: ...chieve the correct CO2 reading shown in the table below Clockwise to decrease anti clockwise to increase Minimum rate adjustment Adjust the modulation rate to minimum 0 as described on page 19 Allow combustion and flame to stabilise then compare CO2 reading to that given in the table below To adjust remove adjustment cover with a flat blade screwdriver Using a 40Torx driver adjust CO2 Clockwise to...

Страница 21: ... operation Regular attention will also prolong the life of the boiler and should preferably be performed at the end of the heating season After servicing complete the service section of the log book and return to the owner or their representative Recommend that a contract for this work should be made with the regional gas authority or a Gas Safe Registered Engineer In IE servicing work must be car...

Страница 22: ...22 Notes ...

Страница 23: ...23 ...

Страница 24: ...24 FERROLI S p A Via Ritonda 78 a 37047 San Bonifacio Verona ITALY www ferroli it ...

Отзывы: