background image

12 

 

 

Hydraulic motor solenoid valve current monitor

 

The current of the proportional solenoid valve connected to the hydraulic motor can be displayed 
on this page in real time.

 

 

 
 

 

 

RS-485 serial ports test (COM Test) 

 

This is a page reserved for Ferrari Costruzioni Meccaniche technical staff for testing functionality of 
the RS-485 serial communication ports.  

 

 
 

 
 

 

3.4   OPTIONAL OUTPUTS: 

 

 

“ON-OFF MICRO” OUTPUT: 

The PSC "ON-

OFF MICRO” output (see 4.WIRING DIAGRAM) is activated when the machine is in 

motion and deactivated when the machine is stationary. It can therefore be used to connect to a 
user (for example a granulator applicator) with the aim of optimising product supply.

 

 
 

 

“PWM MICRO” OUTPUT

 

 

The  PSC  "PWM  MICRO”  output  (see  4.WIRING  DIAGRAM)  provides  an  output  voltage 

proportional  to  the  travel  speed.  It  can  therefore  be  used  to  connect  to  a  user  (for  example  a 
granulator  applicator)  with  the  aim  of  obtaining  the  amount  of  product  proportional  to  the  travel 
speed

 

  

 

3.5   NOTE:  

TOTAL PLANTS:  

 

50,000,000  

TOTAL HOURS:  

 

10,000  

TOTAL HECTARES:   

5,000  

 
PARTIAL PLANTS:    

5,000,000  

PARTIAL HOURS:    

10,000  

PARTIAL HECTARES:  

50 

 

 

 

 

Содержание PSC

Страница 1: ...panel with LCD screen you can set the distance in a range from 1 to 99 9 centimetres with a resolution of 1 millimetre display in real time the travel speed the speed in plants hour and plants hectare...

Страница 2: ...roll through the Historical Data pages Historical Data pages 1 Total and partial plants transplanted 2 Total and partial working hours 3 Total and partial hectors worked 2 2 PROGRAMMING MENU On the Wo...

Страница 3: ...ess or to modify the transplanting distance on a row with resolution of 0 1 cm When you have set the distance press Enter O briefly again to confirm plants and arrows stop blinking Change data display...

Страница 4: ...ultaneously press and on the Work menu for at least 2 seconds to open the PROGRAMMING MENU In the programming menu you can set the machine parameters and some test pages use and to scroll through the...

Страница 5: ...nt of the transplanting bodies at a certain travel speed Press Enter o to enable or disable simulation the word OFF is replaced with an analogue bar that indicates the simulation speed in km h Use and...

Страница 6: ...ay This simulation can be useful for evaluating actual operation of the hydraulic motor the proportional valve the hydraulic system and the mechanical system Furthermore this mode can be useful for di...

Страница 7: ...oder Motor 2400 Note Calibration of parameters in the field the set values are theoretical and must therefore be checked in the field If the distance detected is less than the one set increase the Enc...

Страница 8: ...duty cycle of the PWM wave that excites the proportional solenoid valve In normal conditions the value to be set is 100 Hydraulic motor proportional solenoid valve PWM wave frequency Freq PWM Indicate...

Страница 9: ...ference speed Vel MaxMicro parameters can be changed The system adjusts the duty cycle of the output wave according to a linear feature between the minimum duty and the maximum duty 100 with respect t...

Страница 10: ...n speed of the hydraulic motor PID control derivative action coefficient Kd PID This page shows the derivative action coefficient of the PID control that manages rotation speed of the hydraulic motor...

Страница 11: ...r coefficient Spike filter Indicates the filter coefficient that prevents any spikes on the encoder signals from distorting the angular speed of the sensor It indicates the number of values analysed b...

Страница 12: ...is activated when the machine is in motion and deactivated when the machine is stationary It can therefore be used to connect to a user for example a granulator applicator with the aim of optimising p...

Страница 13: ...4 WIRING DIAGRAM 4 1 PSC SLAVE BOARDS CONNECTION DIAGRAM NOTES In the event of a structure with PSC SLAVES it is necessary to enable the relative setting from the RESERVED PROGRAMMING MENU chapter 3...

Страница 14: ...block faulty motor encoder proportional solenoid valve blocked faulty PSC electronic board ALARM 3 DESCRIPTION PROBLEM Incorrect supply voltage Poor performance of tractor alternator problems with el...

Страница 15: ...15 6 PROGRAMMING MENU PARAMETERS LCD Contrast Encoder Wheel Encoder Motor Rows Track Width Mes Unit Duty Min Duty Max Freq PWM PID Time Micro PWM Alarms...

Страница 16: ...ing Menu 3 3 OPERATION AND SOFTWARE 3 3 1 Work Menu 3 3 2 Programming Menu 4 3 3 Reserved Programming Menu Reserved Menu 10 3 4 Optional Outputs 12 3 5 Notes 12 4 WIRING DIAGRAM 13 4 1 PSC SLAVE board...

Отзывы: