9
NEO MEET INSTALLER MANUA
4 LOCAL PROGRAMMING FROM THE MONITOR
MEET monitors allow the programming of basic configuration parameters (block
identification, housing, IP address, etc.) through their own interface and without using a
PC, so that it is possible to leave it ready to complete its configuration later via the web
browser.
All MEET monitors have the same default IP address (10.1.1.1). In order to access them
remotely via web browser, it is necessary to assign them a unique IP address, according
to the requirements of the LAN.
It is therefore necessary to carry out prior planning of the installation, with the IP address
to be assigned to each and every one of the components of the installation (monitors,
panels and guard units).
The default INSTALLER PIN is 6666.
It can be changed later for another of your choice.
For security reasons, if the wrong PIN is entered three times in a row, the device will be
blocked for 60 seconds.
Once the correct PIN has been entered, the INSTALLATION SETTINGS options will
appear:
4.1. INSTALLER ACCESS
From the idle screen, access the installer section by touching the icon
.
Touch the icon
to access the programming parameters through the interface of the
monitor itself.
Identify yourself by entering the INSTALLER PIN through the keypad: