20
NEO MEET INSTALLER MANUAL
5.7. ACTUATORS
Use this section to enable and name the actuators that this monitor can control.
Click on ENABLE the relays to be enabled and write the name or description that should
appear on the monitor when you want to control any of them.
Select the desired activation time with the RELAY TIME between 1 and 60 seconds.
Select SAVE to confirm.
NOTE:
The control of devices by means of actuators requires the module Ref. 1616. Its installation
is explained in section 2.5. Wiring of FERMAX MEET Relay Module Ref. 1616.
ADDITIONAL DOORS
MAIN DOOR
Select this box if the MEET monitor is used in combination with a device that uses SIP
protocol.
DTMF KEY:
Indicate the DTMF number (or combination of numbers) to be generated
when the monitor’s door open button is pressed, to activate the calling SIP panel’s door
opener. They can be numeric characters and special characters such as # or *.
NUMBER OF DOORLOCKS:
Indicate the number of door openers that this monitor will
control. (Between 0 and 4). Depending on the number indicated, the monitor screen will
display additional door icons when you receive a call.
NUMBER OF CAMERA:
Numbers of IP cameras related to the panel, that will be
available to switch during panel call. (0-4 optional).
NOTE:
Additional door openers are connected to a 4-Relay Meet Module Ref. 1491 connected
to panel No.1 of the block where the monitor is installed (MILO DIGITAL, KIN or MARINE
MEET panels only).
Содержание NEO MEET