NEO MEET INSTALLER MANUA

4. LOCAL PROGRAMMING FROM THE MONITOR 

 

4.1.  Installer access 9

 

4.2.  

Basic configuration of the MONITOR

 10 

 

4.3.  

Configuring the alarm settings

 11

 

  4.4.  Enable/disable FUNCTIONS 12 
  4.5.  Enable/disable function ICONS on the monitor 

13

 

  4.6.  Change INSTALLER PIN 14

5.  WEB BROWSER PROGRAMMING 

15

 

5.1.  Device 16

 

5.2.  General 16

 

5.3.  

Network configuration

 17

 

  5.4.  Ip Camera  17 
  5.5.  SIP 

18

 

  5.6.  Advanced 

19

 

  5.7.  Actuators 

20 

  5.8.  PIN Code 

21

 

  5.9.  Restore 

21

2.  INSTALLATION 

5

 

2.1.  Stand placement 5 

 

2.2.  Attaching the monitor to the stand 

5   

 

2.3.  Connection diagram 6 

 

2.4.  Wired alarm and doorbell sensors 6

 

2.5.  Wiring of FERMAX MEET Relay Module Ref. 1616 

7

INDEX

6.  ANNEX  

22

 

6.1. Firmware updates 22

7. REGULATIONS AND CERTIFICATION 23

3. TECHNICAL SPECIFICATIONS 

8

1. DESCRIPTION 4

Содержание NEO MEET

Страница 1: ...NEO MEET INSTALLER MANUAL...

Страница 2: ...FERMAX ELECTR NICA S A U FERMAX ELECTR NICA applies a continuous improvement policy therefore it reserves the right to modify the contents of this document as well as the product features hereof at an...

Страница 3: ...BROWSER PROGRAMMING 15 5 1 Device 16 5 2 General 16 5 3 Network configuration 17 5 4 Ip Camera 17 5 5 SIP 18 5 6 Advanced 19 5 7 Actuators 20 5 8 PIN Code 21 5 9 Restore 21 2 INSTALLATION 5 2 1 Stand...

Страница 4: ...INSTALLER MANUAL 1 DESCRIPTION The following document is the Installation Manual for the NEO 7 MEET monitor with firmware V03 00 Alarm mode LAN status Missed calls Eceived messages Do not disturb Dat...

Страница 5: ...or ethernet cable power supply and accessories if any arrive Use the screws and plugs supplied with the monitor to attach the stand 2 2 ATTACHING THE MONITOR TO THE STAND Once the stand is in place pr...

Страница 6: ...sed with the wall connector Ref 9541 iring diagram normally open sensor Wiring diagram normally closed sensor Wiring diagram normally open sensor option 3C LAN Ethernet connector to the building s LAN...

Страница 7: ...REF 1616 To use the actuator control function a FERMAX MEET Relay Decoder Ref 1616 must be installed The connection to the monitor is through the RS 485 connector as shown in the following diagram Wi...

Страница 8: ...00 mA Working current 500 mA Resolution 800x480 pixels Touch screen Tecnolog a capacitiva Tiempo m ximo Conversation time 120 secs Time to answer the call 35 secs Auto on time 30 secs Maximum recordin...

Страница 9: ...therefore necessary to carry out prior planning of the installation with the IP address to be assigned to each and every one of the components of the installation monitors panels and guard units The...

Страница 10: ...e screen to enter the corresponding programming parameters MONITOR SETTINGS BLOCK Block number of the apartment where the monitor is installed APARTMENT Number of the apartment where the monitor is in...

Страница 11: ...me to give the user time to switch it off Alarm will not be triggered during the arming countdown PANIC The alarm will be triggered silently i e by giving a warning to the control station but without...

Страница 12: ...elay time from the options offered 0 5 15 20 25 40 or 60 seconds MODES Select the MODES in which you want each of the zones to be active according to the type of sensor and the installation carried ou...

Страница 13: ...SSAGE ACTUATORS SOS You can select up to 8 ICONS to be available in the monitor Select wich function ICON do you want be visible in the MAIN MENU The MAIN MENU will show the 8 selected function ICONS...

Страница 14: ...d for security purposes NOTES If the INSTALLER PIN is changed via WEB browser it can be longer and contain alphanumeric characters See section 5 8 PIN CODE But in that case it cannot be used to access...

Страница 15: ...ress can also be changed or consulted via the local programming of the monitor See section 4 2 Basic configuration of the MONITOR Type the IP address of the monitor in the address bar of the browser A...

Страница 16: ...lt value 0 DEVICE TAG Name that will be shown in the monitor when the function INTERCOM is being used SYNC CODE Synchronisation code with the rest of the monitors installed in the same apartment It ha...

Страница 17: ...IP addressing This ensures that each device has a unique IP address in the same installation If a mmonitor has an IP address already assigned to another device on the network an IP CONFLICT prompt wil...

Страница 18: ...in cases where the monitor is to be configured as an extension on a SIP server SIP SERVER Enter the name or IP of the SIP server where the monitor will register DOMAIN Enter the domain of the SIP serv...

Страница 19: ...h the calls will be forwarded These URLs must have one of these formats sip meetme_licensenumber sip fermax com in case of call divert to mobile using the MEET ME App where meetme_licensenumber corres...

Страница 20: ...combination with a device that uses SIP protocol DTMF KEY Indicate the DTMF number or combination of numbers to be generated when the monitor s door open button is pressed to activate the calling SIP...

Страница 21: ...code the new pin and confirm it The new password can have alphanumeric characters and has no limitation on its length However if the password does not contain just 4 numerical digits it cannot be used...

Страница 22: ...ile The firmware update is performed via the MEET System Upgraded Tool V 1 2 exe The procedure for updating the firmware with the corresponding update file is as follows It is possible to update sever...

Страница 23: ...e harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or...

Страница 24: ...Avd Tres Cruces 133 46017 Valencia Spain Contact tec fermax com www fermax com contact For more information visit www fermax com...