background image

-42-

Setting Nameplate Illumination Mode 

There are 3 illumination modes for nameplate indicator, 

Normally on

,

Normally off 

and

 Auto

Normally on is default, to change the setting, please follow the steps:

UNLOCK Indicator:ON
TALK Indicator:OFF

Buzzer

Beep+, Beep

In standby mode, press 

KEY_SET

 button 

three 

times

.

UNLOCK Indicator:ON
TALK Indicator:OFF

Buzzer

Beep+

Press 

KEY_3 

button to set 

the nameplate illumination 

mode to

 Normally on

.

UNLOCK Indicator:ON
TALK Indicator:OFF

Buzzer

Beep, Beep

Press 

KEY_3 

button again

to set the nameplate illumina-

tion mode to

 Normally off

.

UNLOCK Indicator:ON
TALK Indicator:OFF

Buzzer

Beep, Beep,Beep

Press 

KEY_3 

button again 

and again to set the nameplate 

illumination mode to

 Auto

.

Press 

KEY_3

• 

If setting mode has not been exited, you can change the nameplate illumination mode by pressing KEY3 

circularly.

• 

The 

LED_NAME

 indicator will blink all the time until exit out the setting mode.

• 

If without any operation in 10 seconds, it will exit out setting mode automatically.

• 

In this step,press 

KEY_SET

 button twice to exit out the setting mode manually.

Setting Night View LED Illumination Mode

There are 3 working modes for night view LED indicator, 

Normally on

,

Normally off 

and

 Auto

Auto is default, to change the setting, please follow the steps:

UNLOCK Indicator:ON
TALK Indicator:OFF

Buzzer

Beep+, Beep

In standby mode, press 

KEY_SET

 button 

three 

times

.

UNLOCK Indicator:ON
TALK Indicator:OFF

Buzzer

Beep+

Press 

KEY_4 

button to set 

the night view LED mode 

to

 Normally on

.

UNLOCK Indicator:ON
TALK Indicator:OFF

Buzzer

Beep, Beep

Press 

KEY_4 

button again

to set the night view LED 

mode to

 Normally off

.

UNLOCK Indicator:ON
TALK Indicator:OFF

Buzzer

Beep, Beep,Beep

Press 

KEY_4 

button again

and again to set the night 

view LED mode to

 Auto

.

Press 

KEY_4

• 

If setting mode has not been exited, you can change the night view LED illumination mode by pressing 

KEY4 circularly.

• 

The 

LED_NAME

 indicator will blink all the time until exit out the setting mode.

• 

If without any operation in 10 seconds, it will exit out setting mode automatically.

• 

In this step,press 

KEY_SET

 button twice to exit out the setting mode manually.

Содержание FVI-6010

Страница 1: ...2 2 WIRE SYSTEM VIDEO DOOR PHONE SYSTEM Please read this manual carefully before using the product you purchase and keep it well for future use Please note that images and sketch maps in this manual m...

Страница 2: ...function 22 Viewing calling records 23 Message function 24 Openning staircase light 25 Motion detect function 26 Setting date and time 27 Setting ring tone 28 Setting ring volume 28 Enabling Disablin...

Страница 3: ...s 40 Setting Unlock Mode 41 Setting Unlock Time 41 Setting Nameplate Illumination Mode 42 Setting Night View LED Illumination Mode 42 Setting Ring back Tone 43 Registering ID Card 43 Connecting Electr...

Страница 4: ...Press to view the outdoor condition in standby mode 3 Menu button Press to open main menu in shortcut 4 Unlock button Press to release the door 5 Microphone Transmit audio from one station to other st...

Страница 5: ...t 13 Screw hole Terminal Description 1 2 3 4 5 6 ON DIP L2 L1 DIP Switches SW SW RING GND NC L1 L2 1 2 3 ON DIP 4 5 6 L1 L2 Bus line terminal SW SW Extra door bell call but ton connection port Ring GN...

Страница 6: ...o the bus line no polarity PL External lock power input connect to the power positive power S Lock power output S Lock power output connect to the power input of locks only when using the door station...

Страница 7: ...5 160 cm 1 2 3 4 5 AcDbMLeader ACDB_MLEADER_CLASS AcDbMLeader ACDB_MLEADER_CLASS Rainy cover Rainy cover The distance between the top of main unit and rain cover should be not less than 3mm Main unit...

Страница 8: ...re 3 Use Table below for Dip switch Addressing Master Addressed as 0 For slave monitor 1 Addressed as 1 For slave monitor 2 Addressed as 2 1 Accessing to programming menu Monitors 2 Programming Monito...

Страница 9: ...OK Access to programming menu Figure 3 and input one of the following codes followed by OK button Turn the Green Light off 8057 Turn the Green Light on 8052 3 Unlock Time 4 Monitor button light ON 1 O...

Страница 10: ...ic latch EB Exit button Door lock control is not timed by the exit button See Figure 1 press KEY_SET button then press KEY_ X once where X goes from 1 4 wait 10 seconds or press KEY_SET button four ti...

Страница 11: ...ON DETECT Touch it to enter motion detect options MONITOR Touch it to view outdoor condition MESSAGE Touch it to write messages or review the received sent out messages MEDIA Touch it to play recorded...

Страница 12: ...s and adjust screen volume are available More details please refer to the following descriptions Note 1 If nobody answers the phone the screen will be turned off automatically after 40 seconds 2 The 5...

Страница 13: ...is forbidden Conclude current talking to answer the new call in The talking will stop immediately call tone sounds in normal The video image from the door station is displayed on the screen talking u...

Страница 14: ...ome examples Touch icon to zoom the center position Note 1 The zoom pantilt function should make effective with fish eye door station 2 The edge of pantilt image will not be displayed When an image at...

Страница 15: ...ness and color You should know that the contrast brightness and color can be modified freely but this action should be at the User scene mode Volume can be adjusted at any time Adjusting range 0 mute...

Страница 16: ...the call Note that all other monitors will not open the screens 2 Touch Inner Call icon on one of monitor all other monitors in the same room will ring at the same time whichever monitor answers the c...

Страница 17: ...r select page Note Press TALK MON button on the panel in standby mode to monitor the master door station in shortcut Monitoring door stations cameras DS1 4 and CAM1 4 can be selected to monitor indivi...

Страница 18: ...Pantilt zoom Adjusting images image scale bright color contrast Door release Volume control Manual recording Videos and images are possible to be recorded both automatic recording and manual record i...

Страница 19: ...zoom mode Manual recording cannot be performed during automatic recording Viewing images videos The recorded images videos can be playback on monitor Follow the steps On main menu page touch Media Gra...

Страница 20: ...lders exceed the limit of micro SD card they cannot be copied The images on the micro SD card cannot be copied into the built in memory If copied is fail try to format the SD card on the monitor 20151...

Страница 21: ...function please follow the steps Two modes can be selected Leave a Message Immediately If you select this mode when receiving calls from door sta tion The system will prompt visitor to leave a voice m...

Страница 22: ...perform immediately if selected and the status bar on main menu page will show icon Touch icon on the screen to exit You can review who is visiting at some time 1 Touch one of the visiting list 2 Touc...

Страница 23: ...ller s image Call Record 01 05 06 23 15 22 Calo Liu 06 18 20 54 Smith 06 12 11 06 Vincent Yang 05 29 08 39 Allen Chen 05 27 21 43 Hebe Zhang 04 20 13 16 Ben Wu Call Record 01 05 06 23 15 22 Calo Liu 0...

Страница 24: ...ges On main menu page touch Message Outbox icon the most recent sent out messages will be displayed Select one of the messages to view the contents Note It s available to reply messages or delete mess...

Страница 25: ...sor Opening staircase light Note The staircase light should be connected on the system and this function should be sup ported by RLC Please refer to RLC user instruction in detail Touch Light icon on...

Страница 26: ...tection should be activated individually Detection once respond motion detect function immediately the door station motion detec tion should be activated individually The door station is equipped with...

Страница 27: ...change the value 3 When the setting has finished touch to save the settings The following is taken door station1 for example 1 On main menu page touch icon 2 Touch DS1 Detection item the door station...

Страница 28: ...uch the setting target of door tone intercom tone door bell tone and alert tone individually then touch icon to change the tone Settings will perform immediately The day night ring volume can be set i...

Страница 29: ...g the on screen keypad Up to 12 characters can be entered for a name Enabling Disabling the operation sound You can make a beep sound for the monitor when touching the screen 1 On main menu page touch...

Страница 30: ...tings will perform immediately Enabling Disabling motion detect function You can make it possible ENABLE or not DISABLE to activate motion detect function from this monitor 1 On main menu page touch s...

Страница 31: ...get language is not found in the window touch icon to scroll next page Changing the display language Language English Turkish Greek Hebrew Spanish French Enabling Disabling intercom function You can e...

Страница 32: ...will be sent out Restoring to default setting About Local Address 00 00 Video Standard AUTO System Verson 00 01 00 Display Driver 1 0 Font 1 0 UI 1 0 Logo icon On main menu page touch Logo icon to ent...

Страница 33: ...UI Code Update 2812 Consumer Tune Update 2813 Format SD Card INSTALLER SETUP 123 _ OK Help Menu OK Address Setting Menu Code Setting Item Code Setting Item 2412 Reset to Default Setting 8018 8020 Vid...

Страница 34: ...Address setting page select DIP Switcher Set Address setting mode firstly then touch icon total 32 DIP codes will be displayed DIP Switcher Set Address The DIP switches are used to set the user code...

Страница 35: ...the section of Setting Slave Monitor 1 On Address setting page select Manual Input Address setting mode then touch icon a keypad will be displayed 2 Input the code by touching the digital number 3 To...

Страница 36: ...L2 PL S S ID 0 Code 0 DIP6 on 1 2 3 4 5 6 ON DIP L2 L1 DIP Switches FVI 6017PC6 AC 100 240VAC RF CARD 100 240VAC FVI 6011DBC4A A B C D OFF ON Impedance switch BUS IM BUS DS FVI 6017PC6 AC ID 0 1st do...

Страница 37: ...system and IN OUT mode is recom mended For the last monitor connected to the system DIP6 should set to ON ID 0 Code 0 DIP6 off Code 14 DIP6 off Code 15 DIP6 on BUS IM BUS DS FVI 6017PC6 AC 100 240VAC...

Страница 38: ...I 6017PC6 AC 100 240VAC Optional functional module BDU BDU bus amplifier module RLC staircase light controller module FVI 6011DBC4A 2 4 inputs branch distributor Code 0 DIP6 on Code 2 DIP6 on Code 3 D...

Страница 39: ...unit and by the sounding of the buzzer Order Setting items Setting range Default value 1 Setting door station address 0 3 0 2 Setting the unlock mode 0 opened 1 closed 0 opened 3 Setting the unlock t...

Страница 40: ...tation Press KEY_4 button to set the fourth door station UNLOCK Indicator OFF TALK Indicator OFF Buzzer Beep Beep UNLOCK Indicator OFF TALK Indicator OFF Buzzer Beep Beep Beep UNLOCK Indicator OFF TAL...

Страница 41: ...ing mode manually Setting Unlock Mode There are 2 unlock modes Normally opened and Normally closed Normally opened is default to change the setting please follow the steps UNLOCK Indicator ON TALK Ind...

Страница 42: ...xit out setting mode automatically In this step press KEY_SET button twice to exit out the setting mode manually Setting Night View LED Illumination Mode There are 3 working modes for night view LED i...

Страница 43: ...icator ON Buzzer Beep Beep Beep Press KEY_1 button again and again to close ring back call tone Press KEY_1 If setting mode has not been exited you can change the ring back tone by pressing KEY1 circu...

Страница 44: ...exit out the master card authorized mode If without any operation in 10 seconds it will exit out setting mode automatically It will exit out setting mode automatically after showing these two cards th...

Страница 45: ...NLOCK Indicator OFF TALK Indicator OFF Buzzer Beep Beep Show the master card of MASTER CARD DELETE again to exit UNLOCK Indicator ON TALK Indicator OFF Buzzer Beep Beep Show the master card of MASTER...

Страница 46: ...Unlock Mode 1 Take off the jumper 1 2 3 L1 L2 PL S S LOCK POWER SUPPLY DT RLC relay actuator is needed for 2nd lock connection Connecting Electric Lock Door Lock Controlled with Internal Power 1 Elect...

Страница 47: ...in the DT system Using different cables may also affect the maximum distance which the system can reach Cable and distance unit m Cable Usage A B 2 IM B 16 IM Twisted cable 2x0 75mm2 60 100 40 Twisted...

Страница 48: ...48 B A C 2 2 FVI 6011DBC4A FVI 6017PC6 RF CARD Cable and distance unit m Cable Usage A B C Twisted cable 2x0 75mm2 60 60 30 Twisted cable 2x1mm2 80 80 40 Star Topology Wiring Mode With FVI 6011DBC4A...

Страница 49: ...99s Lock Power supply 12Vdc 280mA Internal Power Number of relay circuits 2 the second lock need external device to support Screen 7 Inch digital color TFT Display Resolutions 800 3 R G B x 480 pixels...

Страница 50: ...50 Note...

Страница 51: ...51...

Страница 52: ...52 The design and specifications can be changed without notice to the user Right to interpret and copyright of this manual are preserved FVI 6010 V2...

Отзывы: