5
Connection diagram
The MEET monitor is connected to the installation by means of connectors: ethernet for LAN
connection and MOLEX type connectors for other connections (power supply, RS-485 and
sensor inputs).
A bag containing the corresponding male plugs with their cables is enclosed with the monitor´s
connector.
•
LAN#1
: Ethernet connector to the building's LAN installation. PoE for WIT monitors. No
PoE for MIO monitors.
•
LAN#2:
Ethernet connector to the home’s local LAN installation. Only WIT 10” monitor.
•
+12V:
12 Vcc power input for non-PoE installations.
•
Siren / Sensors
:
o
S
: 12 Vdc auxiliary output synchronised with the activation of any sensor.
The maximum current is 100 mA.
o
-
: GND.
o
Z1-Z7
: sensor inputs.
Z8
is reserved for tamper.
•
12V +
,
-
,
485+
,
485-
: Power output and RS-485 connection for the 10 Relay Module
Ref. 1616.
NOTE:
LAN#2 connection requires a DHCP server, as it is not possible to assign an IP address from
the monitor.