Ferm GRM1023 Скачать руководство пользователя страница 7

7

EN

 CAUTION: NEVER disconnect the high-
pressure discharge hose from the 
machine while the system is still 
pressurized. To depressurize the unit, 
turn off the motor, turn off the water 
supply and squeeze the trigger 2-3 times.

Water supply

•   Ensure that you have a suitable water supply 

to feed the pressure washer. Check that all 
connections are tight and there are no leaks in 
the hose.

•   The supply tap should be fully open (do not 

turn on the pressure washer yet).

•   Now depress the trigger (unlock trigger lock 

first) to let water pass through the unit and 
expel any air.

Warning! This unit is to be used with a 
cold-water source only!

Electrical Cables

•   Ensure that all cables are damage free before 

connecting to the power supply. 

   Plug in the pressure washer and turn the unit 

on with the main switch (2).

4. USE

CAUTION! The machine may cause 
electrical disturbances when starting.

•   If the motor stops and fails to restart, wait 2-3 

minutes before restarting. THERMAL CUTOUT 
TRIPPED

Adjusting the nozzle

Fig. 2

•   Water may be sprayed out of the nozzle either 

linearly or in a fan shape. Turn on the pressure 
first, and then adjust the nozzle.

Adjusting te working pressure 

Fig. 3

The working pressure can be adjusted by turning 
the sleeve on the end of the spray gun (9).
•   Turn the sleeve clockwise to increasing the    

  working pressure.

•   Turn the sleeve counter-clockwise to reduce   

  the working pressure.

Water inlet filter 

•   The water inlet filter must be inspected regu-

larly, so as to avoid blockage and restriction of 
the water supply to the pump.

CAUTION!  Never disconnect the high-
pressure hose from the machine while 
the system is still pressurized.  

5. SERVICE & MAINTENANCE

Warning! Unplug the electric cable 
(power source) prior to any maintenance 
or preparatory storage operations.

•   Make sure that the machine is not live when 

carrying out maintenance work on the motor.

•   To ensure good performance, check and clean 

the suction and detergent filters after every 50 
hours of operation.

Malfunction

Should the machine fail to function correctly, a 
number of possible causes and the appropriate 
solutions are given below:

1.   When switched on, the machine will not 

start working.

•   Plug is not well connected or electric socket is 

faulty.

  •  Check plug, socket and fuse.

•   The mains voltage is lower than the minimum 

requirement for start up.

  •  Check that the mains voltage is adequate.

•  The pump is stuck.

  •   Refer to after storage instructions. Switch 

off the unit and let the motor cool.

•  Thermal safety has tripped.

  •   Leave the lance open with water coming 

through.

2.  Fluctuating pressure

•  Pump sucking air

  •   Check that hoses and connections are airtight

•   Valves dirty, worn out or stuck. Pump seals worn.

  •  Clean and replace or refer to dealer.

3.  Water leaking from the pump

•  Seals worn out

  •  Check and replace, or refer to dealer

Содержание GRM1023

Страница 1: ...WWW FERM COM EN FR Original instructions 03 Traduction de la notice originale 09 GRM1023...

Страница 2: ...2 Fig 1 Fig 2 Fig 3 1 3 7 2 8 11 9 5 10 4 13 6 12 3 12 5...

Страница 3: ...Spray gun holder 7 Handle 8 Hose hook 9 Spray gun 10 Adjustable Spray Lance 11 Turbo lance 12 Inlet filter 13 High pressure hose 2 SAFETY INSTRUCTIONS Explanation of the symbols Denotes risk of perso...

Страница 4: ...ust be used standing on a secure stable surface Avoid unintentional firing of the trigger Do not carry the lance trigger assembly with your hand over the trigger Always use the trigger lock mechanism...

Страница 5: ...support Keep good footing and balance at all times Follow the maintenance instructions specified in the manual This machine must be grounded If it has malfunction or breakdown grounding provides a pa...

Страница 6: ...2MPa The inlet pipe should at least 5 M long Do not use the pipe if the pipe is damaged If you want connect this machine to portable water mains you must install a backflow preventer in the water pipe...

Страница 7: ...creasing the working pressure Turn the sleeve counter clockwise to reduce the working pressure Water inlet filter The water inlet filter must be inspected regu larly so as to avoid blockage and restri...

Страница 8: ...ces can damage the plastic parts Lubrication The appliance does not need any extra lubrication Storage and transportation Keep the high pressure washer in well ventilated dry premises with temperature...

Страница 9: ...e l eau max 50 C D bit d eau max 6 5 l min Poids 12 7 kg Classe IP IPX5 LWA Puissance acoustique 86 dB A Valeur Vibrations 2 0 m s2 Informations sur le produit Fig 1 1 Nettoyeur haute pression 2 Inter...

Страница 10: ...N obstruez pas les grilles d a ration pendant le fonctionnement La section des rallonges utilis es doit tre proportionnelle leur longueur Cela signifie que plus le c ble est long plus la section doit...

Страница 11: ...e il est recommand d utiliser un enrouleur qui maintienne la prise au moins 60 mm au dessus du sol Afin d viter un risque d la r initialisation intempestive du coupe circuit thermique cet appareil ne...

Страница 12: ...as la machine dans un lieu trop froid afin d viter qu elle ne g le Cette machine a t con ue pour n utiliser que de l eau de lavage n utilisez pas de produits chimiques corrosifs Utilisez le d tergent...

Страница 13: ...teignez TOUJOURS le moteur de l appareil AVANT de couper l arriv e d eau Le moteur peut tre gravement endommag si l appareil fonctionne sans eau ATTENTION Ne d branchez JAMAIS le tuyau de d charge de...

Страница 14: ...sante La pompe est coinc e R f rez vous aux instructions concernant la sortie d hivernage Eteignez l appareil et laissez le moteur refroidir Le coupe circuit thermique s est d clench Laissez la lance...

Страница 15: ...indiqu e sur la carte de garantie Un plan avec les pi ces d tach es pouvant tre obtenues est inclus la fin de ce manuel d utilisation ENVIRONNEMENT Afin d viter tout dommage pendant le transport l ap...

Страница 16: ...16...

Страница 17: ...17...

Страница 18: ...sing 19 410104 Sawtooth gasket ass 23 410105 Right foot 25 410106 Left foot 26 410107 Filtered inlet connector 27 410108 Button 28 410109 Button plate 29 410110 Front housing plate 30 410111 Front hou...

Страница 19: ...19 Exploded view A...

Страница 20: ...bracket 3 pcs B15 410982 Water seal 3 pcs B16 410983 Inlet checking valve 3 pcs B17 410984 Pump cover B18 410985 O ring 5 5x2mm B19 410986 Bolt M8x10mm B20 410987 Outlet checking valve 3 pcs B21 4109...

Страница 21: ...21 Exploded view B...

Страница 22: ...22...

Страница 23: ...utstyr DA Vi erkl rer under eget ansvar at dette produkt er i overensstemmelse med f lgende standarder og bestemmelser er i overensstemmelse med direktiv 2011 65 EU fra Europa Parlamentet og R det af...

Страница 24: ...WWW FERM COM 2018 FERM B V 1807 16...

Отзывы: