1.  I

ntroductIon

 

 

1.1 

Important Safety Information 

4

2.  G

eneral

 I

nformatIon

 

and

 r

atInGs

 

7

3.  m

echanIcal

 I

nstallatIon

 

9

  3.1 General 

9

 

3.2  Before Installation 

9

 

3.3  UL Compliant Installation 

9

 

3.4  Mechanical dimensons and mounting IP66 

9

 

3.5   Mechnical dimensions and mounting IP55 

10

 

3.6  Guidelines for enclosure moutning IP55 & 66  11

 

3.7  Removing the Terminal Cover 

11

 

3.8  Lock off 

14

4.  e

lectrIcal

 I

nstallatIon

 

15

 

4.1   Grounding the Drive 

15

 

4.2  Wiring Precautions 

16

 

4.3  Incoming Power Connection 

16

 

4.4  Drive and motor connection 

16

 

4.5  Motor Terminal Box Connections 

17

 

4.6 

Motor Thermistor Connection 

17

 

4.7 

Control Terminal Wiring 

17

 

4.8  Control Terminals Connection Diagram 

18

 

4.9 

Control Terminal Connections 

18

5.  m

anaGInG

 

the

 K

eypad

 

19

 

5.1  Keypad Layout and Function 

19

 

5.2  Changing Parameters 

19

 

5.3  Accessing and changing parameter values 

20

 

5.4  Keypad Layout and Function OLED 

21

 

5.5  Drive Operating Display OLED 

21

 

5.6  Accessing and Changing Parameter Values OLED  21

 

5.7  Resetting Parameters to Factory Default OLED  22

 

5.8  Resetting Parameter to Use Default Settings  22

 

5.9  Changing the Language on OLED Display 

23

 

5.10  Selecting between Hand and Auto Control OLED 23

6.  c

ommIssIonInG

 

24

7.  hVac s

pecIfIc

 f

eature

 s

etup

  

25

 

7.1 

Pump Staging DOL Cascade 

25

 

7.2   Pump Staging Multiple Drive Cascade 

27

 

7.3 

Maintenance Internal Set-up & Reset 

28

 

7.4 

Load Profile Monitoring Function 

30

 

7.5 

Pump Clean Function 

31

 

7.6 

Pump Stir Function 

33

 

7.7 

Bypass Control Fuction 

33

 

7.8 

Fire Mode Function 

35

 

7.9 

Motor Pre-heat Function & DC Injection 

37

8  pId c

ontrol

 a

pplIcatIons

 

39

  8.1 Overview 

39

 

8.2  PID Function Set-Up 

39

 

8.3  Application Example 

43

9.  p

arameters

 

44

10. d

IGItal

 I

nput

 f

unctIons

 

46

 

10.1  Digital Input Configuration Parameter P1-13 

46

11.  e

xtened

 p

arameters

 

47

 

11.1  Parameter Group 2 - Extended 

47

 

11.2  Parameter Group 3 - PID Control 

52

 

11.3  Parameter Group 4 - Motor Control 

53

 

11.4  Parameter Group 5 - Communication 

53

 

11.5  Parameter Group 6 - Advanced Features 

54

 

11.6  Parameter Group 8 - HVAC Functions 

55

 

11.7  Parameter Group 9 - Advanced Control Logic  57

 

11.8  Parameter Group 0 - Monitoring 

57

12. s

erIal

 c

ommunIcatIons

 

61

 

12.1  RS-485 Communications 

61

 

12.2  Modbus RTU Communications 

61

13. t

echnIcal

 d

ata

 

63

  13.1 Environmental 

63

 

13.2   Input Voltage Ranges 

63

 

13.3  Maximum Supply Ratings for UL Compliance  63

 

13.4  Output Power & Current Ratings 

64

 

13.5  Additional Information for UL Approved 

65

14. p

arameter

 c

hanGe

 t

ables

 

66

15. t

roubleshootInG

 

67

 

Содержание QD:HVAC

Страница 1: ...Installation and Operating Instructions AC Variable Speed Drive 0 75kW 160kW 200 480 Volt 1 3 Phase...

Страница 2: ...ecommended Use a screened shielded cable The shield should be bonded to earth at both ends Motor Connection Check for Star or Delta Connection Enter the Motor Nameplate data into the drive param eters...

Страница 3: ...r voltage rating see page 17 Enter the Motor Nameplate data into the drive parameters as follows l Motor RatedVoltage P1 07 l Motor Rated Current P1 08 l Motor Rated Frequency P1 09 l Motor Rated Spee...

Страница 4: ...pment into which this product is incorporated must comply with the EMC Directive 2004 108 EC When using an Fenner drive with an internal or optional external filter compliance with the following EMC C...

Страница 5: ...nging the Language on OLED Display 23 5 10 Selecting between Hand and Auto Control OLED23 6 Commissioning 24 7 HVAC Specific Feature Setup 25 7 1 Pump Staging DOL Cascade 25 7 2 Pump Staging Multiple...

Страница 6: ...er control cabling is close to power cabling maintain a minimum separation of 100 mm and arrange crossings at 90 degrees Ensure that all terminals are tightened to the appropriate torque setting Do no...

Страница 7: ...40 110 6 575F3037 37 50 150 6 575F3045 45 60 180 6 575F3055 55 75 202 6 575F3075 75 100 240 7 575F3090 90 120 300 7 kW Model with Filter 22kW HP Output Current A Frame Size 575F40P7 0 75 1 2 2 2 575F4...

Страница 8: ...utput Current A Frame Size 576F20P7 0 75 1 4 3 2 576F21P5 1 5 2 7 2 576F22P2 2 2 3 10 5 2 kW Model with Filter kW HP Output Current A Frame Size 576F40P7 0 75 1 2 2 2 576F41P5 1 5 2 4 1 2 576F42P2 2 2...

Страница 9: ...of the correct type and power requirements for the application Store the QD HVAC in its box until required Storage should be clean and dry and within the temperature range 40 C to 60 C 3 3 UL Complia...

Страница 10: ...33 4 25 0 167 7 5 0 295 5 540 21 26 515 20 28 520 20 47 8 0 315 270 10 63 235 9 25 175 6 89 4 25 0 167 7 5 0 295 6 865 34 06 830 32 68 840 33 07 10 0 394 340 13 39 290 11 42 200 7 87 5 5 0 217 11 0 43...

Страница 11: ...ve Size X Above Below Y Either Side mm in mm in 2 IP66 150 5 9 10 0 394 3 IP66 150 5 9 10 0 394 4 IP55 200 7 9 10 0 394 5 IP55 200 7 9 10 0 394 6 IP55 200 7 9 10 0 394 7 IP55 200 7 9 10 0 394 Note Typ...

Страница 12: ...er slide the top locating lugs upwards under the top cover then re fasten the lower cover screws 3 7 3 Frame Size 4 3 7 2 Frame Size 5 Using a suitable flat blade screwdriver rotate the four retaining...

Страница 13: ...www fptgroup com HVAC Installation Operating Instructions Page 13 3 7 4 Frame Size 7 Using a suitable flat blade screwdriver rotate the four retaining screws indicated until the screw slot is vertical...

Страница 14: ...erating Instructions Page 14 3 8 Lock Off Power Isolator Lock Off IP66 with Built in Isolater Option On the switched models the main power islator switch can be locked in the off position using a 20mm...

Страница 15: ...nections should be checked periodically 4 1 2 Protective Earth Connector The cross sectional area of the PE Conductor must be at least equal to that of the incoming supply conductor 4 13 Safety Ground...

Страница 16: ...inutes should be allowed before removing the terminal covers or connection The maximum permissible short circuit current at the Fenner drive Power terminals as defined in IEC60439 1 is 100kA An option...

Страница 17: ...ermistor Connection Where a motor thermistor is to be used it should be connected as follows 1 2 8 7 6 5 4 3 10 9 ControlTerminal Strip Additional Information Compatible Thermistor PTC Type 2 5k trip...

Страница 18: ...A for user potentiometer 6 AI 1 Input 4 Digital 8 30V DC Analog Input 1 10 to 10V 0 4 to 20mA 7 0V 0 Volt Common 8 AO1 Output 1 1st Analog Digital Output 0 to 10V 4 to 20mA or 24VDC Digital 9 0V 0 Vol...

Страница 19: ...arameter edit mode DOWN Used to decrease speed in real time mode or to decrease parameter values in parameter edit mode RESET STOP Used to reset a tripped drive When in keypad mode is used to Stop a r...

Страница 20: ...ess Display shows P1 01 Select lowest Group Parameter Px xx The first parameter of a group is selected Display shows P1 10 Press Display shows P1 01 Set Parameter to minimum value Any numerical value...

Отзывы: