Relay type 

3 contacts (Com, NC, NO)

Maximum current 

8A (resistive load)

Voltage 

250 Vac continuously

Instalable in 

Option1 and/or Option2

A  B  C  D  E

Common

NC

NO

K  L  M  N

F  G  H  I  J

Common

NC

NO

O  P  Q  R

Connections for Option1

Connections for Option2

Manufacturer  FEMA ELECTRÓNICA, S.A.

 

Altimira 14 - Pol. Ind. Santiga

 

E08210 - Barberà del Vallès

 

BARCELONA - SPAIN 

 

www.fema.es - [email protected]

Products -   S40-T

The manufacturer declares that the instruments indicated 

comply with the directives and rules indicated below.

Directive of electromagnetic compatibility 2004/108/CEE

Directive of low voltage 73/23/CEE

Security rules 61010-1

Equipment “Fixed” 

 

“Permanently connected”

Pollution degree 1 and 2 (without condensation) 

Isolation Double

Emission rules

61000-6-4   Generic rule of emission

Immunity rules

61000-6-2 

Generic rules of immunity

61000-4-2 

By contact ±4KV - Criteria B

 

On air ±8KV - Criteria B

61000-4-3  

Criteria A

61000-4-4   On AC power lines: ±2KV - Criteria B

 

On DC power lines: ±2KV - Criteria B

 

On signal lines : ±1KV - Criteria B

61000-4-5 

Between AC power lines ±1KV - Criteria B 

 

Between DC power lines ±0.5KV - Criteria B

61000-4-6 

Criteria A

61000-4-8 

30A/m at 50Hz - Criteria A

61000-4-11  0% 1 cycle Criteria A

 

40% 10 cycle Criteria B

 

70% 25 cycle Criteria B

 

0% 250 cycle Criteria B

Barberà del Vallès November 2011

Daniel Juncà - Quality Manager

All instruments are warranted against all manufacturing 

defects for a period of 24 MONTHS from the shipment date. 

This warranty does not apply in case of misuse, accident or 

manipulation by non-authorized personnel. In case of mal-

function get in contact with your local provider to arrange for 

repair. Within the warranty period and after examination by 

the manufacturer, the unit will be repaired or substituted when 

found to be defective. The scope of this warranty is limited to 

the repair cost of the instrument, not being the manufacturer 

eligible for responsibility on additional damages or costs. .

You may need to access the inside of the instrument to insert 

additional options. Use a flat screwdriver to unlock the upper 

clips marked with “A”. Then unlock the lower clips marked 

with “B” and move out the front filter. Let the inside of the 

instrument slide out of the housing.

To reinsert the instrument make sure that all modules are 

correctly connected to the pins on the display module. Place 

all the set into the housing, assuring that the modules cor-

rectly fit into the internal guiding slides of the housing. Once 

introduced,  place  again  the  front  filter  by  clipping  first  the 

upper clips “A” and then the lower clips “B”.

Important - If your instrument was delivered with the IP65 front 

seal option, accessing the inside of the instrument will perma-

nently break the IP65 seal on the areas of clips “A” and “B”.

A

B

Option R1 - 1 relay

Warranty

CE Declaration of Conformity

Accessing the instrument

Содержание S40-T

Страница 1: ...th internal CJC selectable enabled or disabled Selectable behavior in case of sensor break to_high or to_low Reduced housing 72x36mm DIN standard Display in 4 digits and negative sign Maximum and mini...

Страница 2: ...on the specified protection level Disconnect the instrument from power before starting any maintenance and or installation action Risk of electrical shock Instrument terminals can be connected to dan...

Страница 3: ...he power line a protection fuse acting as disconnection element easily accessible to the operator and identified as a protection device Power H fuse 250mA time lag Power L fuse 400mA time lag 6 7 8 9...

Страница 4: ...able 3 Offset drift see table 3 Span drift see table 3 Note span drift includes also the offset drift CJC automatic On Off selectable CJC accuracy 1 0 C CJC thermal drift 0 04 C On sensor break to_hig...

Страница 5: ...nu or leaves the Informa tion Menu Operating the Information Menu 36 8 32 5 Mechanical Dimensions mm 72 18 80 69 Panel cut out Configuration Conf Information on the configured input sensor and the deg...

Страница 6: ...the menu Allows selec tion of the current option displayed During a value selection menu for example a setpoint value validates the value on display Button UP Moves vertically on the menu Displays the...

Страница 7: ...tion See menu for Alarm1 See menu for Alarm1 See menu for Alarm1 Alarm1 Setpoint Hysteresis Delay Active On Inactive Off Max Maximum Min Minimum Alarm management Alarm as max Alarm as min Counts Secon...

Страница 8: ...fected on the same way as the setpoint with hysteresis and delays Display Menu Functions on this menu allow for configuration of the visu alization Steps StEP Display changes on predefined steps Value...

Страница 9: ...message h udr Hardware underrange The thermocouple signal is lower than minimum readable signal 30mV h oVr Hardware overrange The thermocouple signal is higher than maximum readable signal 80mV d udr...

Страница 10: ...ber 2011 Daniel Junc Quality Manager All instruments are warranted against all manufacturing defects for a period of 24 MONTHS from the shipment date This warranty does not apply in case of misuse acc...

Страница 11: ...User s Manual S40 T FEMA ELECTR NICA Page 11 T H I S P A G E B L A N K...

Страница 12: ...ucts ELECTRONIC INSTRUMENTATION FOR INDUSTRY www fema es FEMA ELECTR NICA S A Altimira 14 Pol Ind Santiga E08210 Barber del Vall s BARCELONA SPAIN Tel 34 93 729 6004 www fema es Fax 34 93 729 6003 inf...

Отзывы: