User’s Manual S40-T
FEMA ELECTRÓNICA - Page 10
Relay type
3 contacts (Com, NC, NO)
Maximum current
8A (resistive load)
Voltage
250 Vac continuously
Instalable in
Option1 and/or Option2
A B C D E
Common
NC
NO
K L M N
F G H I J
Common
NC
NO
O P Q R
Connections for Option1
Connections for Option2
Manufacturer FEMA ELECTRÓNICA, S.A.
Altimira 14 - Pol. Ind. Santiga
E08210 - Barberà del Vallès
BARCELONA - SPAIN
www.fema.es - [email protected]
Products - S40-T
The manufacturer declares that the instruments indicated
comply with the directives and rules indicated below.
Directive of electromagnetic compatibility 2004/108/CEE
Directive of low voltage 73/23/CEE
Security rules 61010-1
Equipment “Fixed”
“Permanently connected”
Pollution degree 1 and 2 (without condensation)
Isolation Double
Emission rules
61000-6-4 Generic rule of emission
Immunity rules
61000-6-2
Generic rules of immunity
61000-4-2
By contact ±4KV - Criteria B
On air ±8KV - Criteria B
61000-4-3
Criteria A
61000-4-4 On AC power lines: ±2KV - Criteria B
On DC power lines: ±2KV - Criteria B
On signal lines : ±1KV - Criteria B
61000-4-5
Between AC power lines ±1KV - Criteria B
Between DC power lines ±0.5KV - Criteria B
61000-4-6
Criteria A
61000-4-8
30A/m at 50Hz - Criteria A
61000-4-11 0% 1 cycle Criteria A
40% 10 cycle Criteria B
70% 25 cycle Criteria B
0% 250 cycle Criteria B
Barberà del Vallès November 2011
Daniel Juncà - Quality Manager
All instruments are warranted against all manufacturing
defects for a period of 24 MONTHS from the shipment date.
This warranty does not apply in case of misuse, accident or
manipulation by non-authorized personnel. In case of mal-
function get in contact with your local provider to arrange for
repair. Within the warranty period and after examination by
the manufacturer, the unit will be repaired or substituted when
found to be defective. The scope of this warranty is limited to
the repair cost of the instrument, not being the manufacturer
eligible for responsibility on additional damages or costs. .
You may need to access the inside of the instrument to insert
additional options. Use a flat screwdriver to unlock the upper
clips marked with “A”. Then unlock the lower clips marked
with “B” and move out the front filter. Let the inside of the
instrument slide out of the housing.
To reinsert the instrument make sure that all modules are
correctly connected to the pins on the display module. Place
all the set into the housing, assuring that the modules cor-
rectly fit into the internal guiding slides of the housing. Once
introduced, place again the front filter by clipping first the
upper clips “A” and then the lower clips “B”.
Important - If your instrument was delivered with the IP65 front
seal option, accessing the inside of the instrument will perma-
nently break the IP65 seal on the areas of clips “A” and “B”.
A
B
Option R1 - 1 relay
Warranty
CE Declaration of Conformity
Accessing the instrument