FEMA ELECTRÓNICA . Series S . S40-C1

5

Digits

number of digits 

4

led  

7 segments led

color 

red or green

digit height 

14 mm

Reading

maximum reading 

9999

minimum reading 

-1999

decimal point 

configurable X.X.X.X.

overrange / underrange 

configurable  to  flash, reset or preset 

(see 

section 1.19.16)

display refresh 

15 readings / second

memory retention 

yes, retains reading value in case of pow

-

er loss

Signals accepted

 

NPN,  PNP,  Namur,  pick-up,  TTL,  induc

-

tive, mechanical, quadrature, ...

Max. Vdc at 

input 

±30 Vdc

Input impedance

 

2K4 with pull-up or pull-down resistor

 

470K without pull resistor

Accuracy

 of the quartz 

±0.01 %

Thermal drift

 

 

20 ppm / ºC

Excitation voltage

 

configurable

output voltage 

+18 Vdc, +15 Vdc, +9  Vdc, +5 Vdc

maximum current 

70 mA

protection 

yes, current limited to 70 mA

Frequencies 

counter modes 

(see Table 3)

 

ratemeter modes 

(see Table 4)

 

periodmeter modes 

(see Table 5)

Power

power ‘H’ 

85 to 265 Vac/dc

power ‘L’ 

11 to 60 Vdc and 24/48 Vac

isolation* 

2500 Veff with power ‘H’

 

1500 Veff with power ‘L’

 

*tested for 60

sec.

consumption 

<1.5 W only meter

 

<4.0 W meter with options

Configuration

 

3 buttons front keypad

Front protection

 

IP54

Output and control options

  relays, analog outputs, serial communi

-

cations 

(see section 2)

Mechanical

mounting  

panel

connections 

plug-in screw terminal

housing material  

ABS, polycarbonate (V0)

weight  

<150 grams

front size  

72 x 36 mm

panel cut-out  

69 x 32.5 mm

depth from panel  

98 mm (including terminals)

Temperature

 

operation  

from   0   to +50 ºC

storage  

from  -20  to +70 ºC

warm-up time 

15 minutes

Counter

Mode

Frequency

Section

Counter

‘FAST’ mode active max. 250 KHz

1.19.2

normal mode

max. 9 KHz

1.19.2

C inhibition

max. 9 KHz

1.19.4

C control A/S

max. 9 KHz

1.19.5

Counter differential

max. 9 KHz

1.19.6

Counter 

 

quadrature

mode x1

max. 17 KHz

1.19.3

mode x2

max. 16 KHz

1.19.3

mode x4

max. 11 KHz

1.19.3

Table 3 - Maximum input frequency for counter modes

Ratemeter

Mode

Frequency

Section

Ratemeter

normal mode

max. 500 KHz

1.19.7

‘SLOW’ mode ac-

tive

max. 200 Hz

 

min. 1 mHz

1.19.7

Ratemeter 

quadrature

mode x1

max. 17 KHz

1.19.8

mode x2

max. 16 KHz

1.19.8

mode x4

max. 11 KHz

1.19.8

Table 4 - Maximum and minimum input frequency for ratemeter modes

Periodmeter

Mode

Frequency

Section

Periodmeter

normal mode

max. 500 KHz

1.19.9

‘SLOW’ mode ac-

tive

max. 200 Hz

 

min. 1 mHz 

(1000 sec.)

1.19.9

Table 5 - Maximum and minimum input frequency for periodmeter modes

1.12 Mechanical dimensions (mm)

1.11 

Technical specifications

72

36

32,5

69

Panel 

cut-out

18

8

80

Содержание S40-C1

Страница 1: ...with 4 digit display Fast access to alarm setpoints special modes for fast counting and for slow ratemeter applications on power up function configurable reading brightness Universal AC and DC power...

Страница 2: ...15 Direct configuration for most usual sensor at the SnSr Auto menu see section 1 19 10 Function Trigger Sense helps to detect the correct trigger level see section 1 13 Multiple display filters memor...

Страница 3: ...tor 1 to 9999 and configurable divider factor 1 to 9999 For low frequency applications the SLOW mode provides the best response time for each application see section 1 15 Maximum frequency up to 500 K...

Страница 4: ...n sor parameters to the values indicated in the table The table also indicates the typical con nections for each type of sensor Param eters can be manually modified Connections are indicated for a sin...

Страница 5: ...d control options relays analog outputs serial communi cations see section 2 Mechanical mounting panel connections plug in screw terminal housing material ABS polycarbonate V0 weight 150 grams front s...

Страница 6: ...restart power up or configuration change is used for internal initialization and will not be counted as impulse 1 14 Function cycle counter 1 15 SLOW mode The trigger level is automatically configured...

Страница 7: ...ENTER key It selects and accesses the menu option currently dis played At menus with numerical value entries it validates the num ber displayed Key UP 5 the UP 5 key gives access to the fast access me...

Страница 8: ...e Impulses input at channel A Channel B disabled Access the Decimal point dP menu to select the decimal point position Move the decimal point by pressing the LE 3 key Configure the function mode selec...

Страница 9: ...hen channel B is at logical state 1 Select on_0 to inhibit the counting when channel B is at logical state 0 1 19 4 Configuration for cnI 3 Configuration menu for mode counter control add substract cn...

Страница 10: ...in formation on the SLoW mode in case of unstable signals activate the average filter AVr func tion It activates a recursive filter on the reading the filter is stronger for higher values from 0 0 to...

Страница 11: ...the SLoW parameter configuring the tIME parameter between 1 and 1000 seconds Configure the nuMb parameter between 1 and 32 impulses See section 1 15 for more in formation on the SLoW mode in case of u...

Страница 12: ...nnel Act r configures the activa tion of the reset channel by rising edge on_h or by falling edge on_0 Excitation voltage V EXc configures the value of the excita tion voltage at 5 Vdc 9 Vdc 15 Vdc an...

Страница 13: ...s at Deactivation delay dEL 1 configure the delay to apply before alarm deactivation The deactivation delay starts counting when the setpoint value plus the hysteresis value is passed Value from 0 0 t...

Страница 14: ...tpoint2 ALr2 function allows to visualize and modify the alarm2 setpoint through the fast access menu the Memory of maximum MAX or Memory of minimum MIn func tions allow to visualize the maximum or mi...

Страница 15: ...et FAct menu select yes to load the default factory configuration for the instrument see section 1 21 1 19 20 Factory reset 1 19 21 Firmware version 1 19 16 Menus Overrange underrange The Counter over...

Страница 16: ...unter inhibition Multiplier Divider Preset Preset value 1999 to 9999 Mode Up Down Inhibition Inhibits if chan nel B is high Inhibits if chan nel B is 0 Vdc Multiplier 1 to 9999 Divider 1 to 9999 Confi...

Страница 17: ...3 wire PNP 2 wire PNP 3 wire Push pull TTL CMOS Pick up Inductive Vac 30 V Multiplier 1 to 9999 Divider 1 to 9999 Conf ratemeter Multiplier Divider Time window Seconds SLOW mode Average filter Filter...

Страница 18: ...h To zero To preset Counter underrange Flash To zero To preset 1 20 Full configuration menu cont On alarm Continue To zero To preset Alarm 1 Setpoint Hysteresis Setpoint 2 Active Alarm type Alarms Act...

Страница 19: ...ory of cycles 0 Counter overrange flash Counter underrange flash Left zeros off Vexc control off Password off Brightness 3 Alarms 1 and 2 Active off disabled Type maximum Setpoint 1000 Hysteresis 0 co...

Страница 20: ...nt slide out of the housing To reinsert the instrument make sure that all modules are correctly connected to the pins on the display module Place all the set into the housing assuring that the modules...

Страница 21: ...s and regulations 1 25 Warranty This instrument is warranted against all manufacturing defects for a period of 24 MONTHS from the shipment date This warranty does not apply in case of misuse accident...

Страница 22: ...pt 1 Power Signal A B C A B C The R1 module provides 1 relay output to to install at digital panel meters from Series S up to a maximum of 2 relays in a single meter Note for more than 2 relays per in...

Страница 23: ...yed installation as it does not require soldering or special configuration Terminal A Vexc Terminal B Signal in mA or Vdc Terminal C GND Jumper M closed for mA Jumper V closed for Vdc For more informa...

Страница 24: ...ration Terminal B B signal from RS 485 bus Terminal A A signal from RS 485 bus Terminal G GND For more information http fema es docs 4254_SERIES_M K S_ OPTIONS_manual_en pdf Protocol Modbus RTU Functi...

Страница 25: ...up to 31 modules Frames codified in represent able ASCII characters codes 32 to 255 directly visible using hyper terminal or similar programs Access to display values alarm status memory of maximum an...

Страница 26: ...FEMA ELECTR NICA Series S S40 C1 26 Notes...

Страница 27: ...FEMA ELECTR NICA Series S S40 C1 27 Notes...

Страница 28: ......

Отзывы: