FEMA ELECTRÓNICA . Series S . S40-C1
14
1.19 Configuration menu (cont.)
The ‘
On Power Up
’ (‘
on.Pu
’) menu configures functions to apply at
start-up. It applies only to instrument restart after power loss. It does
not apply to instrument restart due to change in configuration.
• parameter ‘
Delay
’ (‘
dLAy
’) assigns a waiting time in seconds. The
instrument waits the configured time before starting normal func
-
tion. During this waiting time, the display shows all decimal points
on in flash mode, all alarms are in ‘oFF’ state, there is no signal acqui
-
sition and there is no communications or control being performed.
After the configured time is over, the instrument starts in normal
function. Delay value between 0 and 200 seconds.
• the ‘
Reset
’ (‘
rSt
’)
parameter will execute a reset of the counter
each time the instrument is restarted.
1.19.15 Menu ‘On Power Up’
Tools
Key UP
(‘fast access’)
Memory of
maximum
Memory of
minimum
Setpoint 1
Setpoint 2
Memory of
cycles
Preset value
On power-up
Delay
Seconds
Reset
The ‘UP’ (
5
) key at the front of the instrument gives access to a list of func
-
tions configurable by the operator. See section
for an explanation on how
to operate the ‘
fast access
’ menu.
The ‘
Key UP (Fast access)
’ (‘
K.uP
’) menu allows to select which functions will
be accessible through the ‘fast access’ menu. Select ‘
on
’ to activate each func
-
tion.
• the ‘
Setpoint
1
’ (‘
ALr1
’) function allows to visualize and modify the alarm
1
setpoint through the ‘fast access’ menu.
• the ‘
Setpoint
2
’ (‘
ALr2
’) function allows to visualize and modify the alarm
2
setpoint through the ‘fast access’ menu.
• the ‘
Memory of maximum
’ (‘
MAX
’)
or
‘
Memory of minimum
’ (‘
MIn
’) func
-
tions allow to visualize the maximum or minimum reading value stored in
memory. To reset this value, visualize the memory value at the ‘fast access’
menu with key UP (
5
) and when message ‘
rSt
’ is displayed, press (
<
) to re
-
set.
• the ‘
Memory of cycles
’ (‘
cYcL
’)
function allow to visualize and reset the
memory of cycles. To reset this value, visualize the memory value at the ‘fast
access’ menu with key UP (
5
) and when message ‘
rSt
’ is displayed, press (
<
)
to reset. The memory of cycles countes ‘+1’ each time a reset alarm occurs
(‘on_AL’ / ‘to_0’ or ‘to_P’) or a reset by ‘overrange’ / ‘underrange’ occurs.
• the ‘
Preset value
’ (‘
PrSt
’)
function allows to visualize and modify the preset
value configured.
1.19.12 Fast access
If only a single function is selected for the ‘fast access’ menu, press
-
ing the the ‘UP’ (
5
) key will shortly display the function name and
then automatically jump to the function value.
1.19.13
Super fast access
The ‘LE’ (
3
) key at the front of the instrument can be configured to
activate several functions. Only one function can be assigned to the
‘LE’ (
3
) key
• the ‘
No function
’ (‘
nonE
’)
value assigns no function.
• the ‘
Front reset
’ (‘
F.rSt
’) value assigns the reset function.
• the ‘
Alarm unlock
’ (‘
A.Lck
’)
value assigns the manual unlock of the
alarms function, for instruments with the ‘
Locked alarms
’ (‘
A.Lck
’)
function activated
• the ‘
Reset and alarm unlock
’ (‘
Fr.AL
’) assigns the two previous
functions to the same button.
1.19.14
Menu ‘Key LE’
Key LE
Front reset
Alarm unlock
No function
Reset and alarm unlock
Содержание S40-C1