11.  Precautions on installation

This instrument is warranted against all manufacturing defects for a 

period of 36 months, as requested by the European legislation. This 

warranty does not apply in case of misuse or accident, and the scope 

of the warranty is limited to repair of the instrument, not being  the 

manufacturer responsible for additional damages or additional costs. 

Within the warranty period and after examination by the manufacturer, 

the unit will be repaired or substituted when found to be defective.
Extended warranty available at (see section 4).

12.  Warranty

Displayed code 

 

 

[10]

Input signal 

4/20 mA 

Output signal 1 

4/20 mA

Output signal 2 

4/20 mA

Password code 

disabled  

[00]

Working mode 

mode 1  

[01]

This  instrument  has  been  designed  and  verified  conforming  to  the 

61010-1 CE Security Regulation, for industrial applications. Installation 

of this instrument must be performed by qualified personnel only. This 

manual contains the appropriate information for the installation. Using 

the instrument in ways not specified by the manufacturer may lead to a 

reduction of the specified protection level. Disconnect the instrument 

from  all  external  circuits  before  starting  any  maintenance  and  /  or 

installation action.
The instrument does not have a general switch and will start operation 

as soon as power is connected. The instrument does not have protection 

fuse, the fuse must be added during installation.
The instrument is designed to be DIN rail mounted, inside a cabinet, 

protected from direct impacts. An appropriate ventilation of the 

instrument must be assured. Do not expose the instrument to excess of 

humidity. Maintain clean by using a humid rag and do NOT use abrasive 

products such as alcohols, solvents, etc. General recommendations for 

electrical installations apply, and for proper functionality we recommend 

: if possible, install the instrument far from electrical noise or magnetic 

field generators such as power relays, electrical motors, speed variators, 

... If possible, do not install along the same conduits power cables 

(power,  motor  controllers,  electrovalves,  ...)  together  with  signal  and/

or control cables. Before proceeding to the power connection, verify 

that the voltage level available matches the power levels indicated in 

the label on the instrument. In case of fire, disconnect the instrument 

from the power line, fire alarm according to local rules, disconnect the air 

conditioning, attack fire with carbonic snow, never with water.

Risk of electrical shock. Instrument terminals can be 

connected to dangerous voltage.

Instrument protected with double isolation. No earth 

connection required.

Instrument conforms to CE rules and regulations. 

Conformity with security regulations EN-61010-1 requires that 

the front cover is closed. The input terminal prevents the front 

cover from opening.

13.  Factory default parameters

Manufacturer 

FEMA ELECTRÓNICA, S.A. 

 

Altimira 14 - Pol. Ind. Santiga 

 

E08210 - Barberà del Vallès  

 

BARCELONA  - SPAIN 

 

www.fema.es - [email protected]

Products  

I3D

The manufacturer declares that the instruments indicated comply with the 

directives and rules indicated below.
Electromagnetic compatibility directive 2014/30/EU 

Low voltage directive 2014/35/EU 

ROHS directive 2015/863/EU 

WEEE directive 2012/19/EU

Security rules EN-61010-1

Instrument  

Fixed, Permanently connected 

Pollution degree   1 and 2 (without condensation)  

Isolation  

Double 

Overvoltage category 2

Electromagnetic compatibility rules EN-61326-1

EM environment Industrial 

CISPR 11  

Instrument Class A & Class B Group 1

For a detailed declaration see section 

4.

 

Barberà del Vallès, October 2022 

Xavier Juncà - Product Manager

According to directive 2012/19/EU, electronic equipment 

must be recycled in a selective and controlled way at the 

end of its useful life.

14.  CE declaration of conformity

RESET TO DEFAULT FACTORY PARAMETERS

To recover the instrument to default factory parameters, select code ‘

16

’ 

and activate value ‘

01

’.

• access the ‘

configuration mode

• access code ‘

16

’ and press key ‘

SQ

’ (

<

)

• the ‘

configuration digits

’ show code ‘

00

’ flashing

• press key ‘

UP

’ (

5

) to change to value ‘

01

• press key ‘

SQ

’ (

<

)

• the leds light a round shape while the new configuration is stored, and 

the instrument returns to ‘

normal mode

’ of operation

• the ‘

configuration  digits

’ show code ‘

10

’ and the default factory 

configuration is now active

FIRMWARE VERSION

The instrument ‘

firmware

’ version is an alphanumerical code from ‘

00

’ to 

FF

’, accessible through configuration code ‘

17

’.

Содержание I3 Series

Страница 1: ...SERIES I3 Model I3D USER S MANUAL ISOLATED SIGNAL DUPLICATOR Section OEM 5577r03 Process 0 10Vdc Process 4 20mA OEM YOURCONVERTER APPLICATIONS www fema es Duplicator Process Double...

Страница 2: ...3 7 Technical specifications 3 8 Connections and dimensions mm inch 4 9 Access the Configuration system 6 10 Operate theconfiguration system 7 10 1 Normal mode of operation 7 10 2 Configuration mode 7...

Страница 3: ...mA active max 20 5mA min 3mA maximum load 400Ohm passive 4 20mA output 4 20mA passive max 30Vdc on terminals OUTPUT SIGNAL2 active 4 20mA output 4 20mA active max 20 5mA min 3mA maximum load 400Ohm pa...

Страница 4: ...on device Use time lag fuse with value 250 mA for voltages 50Vac dc 400 mA for voltages 50Vac dc fuse output 4 20mA passive current out output 4 20mA current in output 4 20mA active current out POWER...

Страница 5: ...c The instrument has two outputs output1 is fixed to 4 20 mA active and passive output2 is fixed to 4 20 mA active and passive To select the active or passive mA versions at the input and output signa...

Страница 6: ...operations must be performed by qualified operators When correctly connected the input signal terminal prevents the front cover from opening ACCESS THE CONFIGURATION SYSTEM Step numbers as referenced...

Страница 7: ...eypad is located inside the instrument behind the removable front cover To access the configuration keypad remove the input signal terminal and open the front cover see section 9 The instrument allows...

Страница 8: ...and return to the Force high Fh menu entry Table 6 Tools menu UP Press UP 5 for 1 second to access the tools menu Force Low Force high Exit 9 Operate theconfiguration system cont HOWTO BLOCK ACCESSTO...

Страница 9: ...rovalves together with signal and or control cables Before proceeding to the power connection verify that the voltage level available matches the power levels indicated in the label on the instrument...

Страница 10: ...fixed to 3mA Possible shortcircuit at input Possible open circuit at input E4 Overload at the 4 20mA input The input signal detected is higher than 90mA The instrument self protection has opened the c...

Страница 11: ...SERIES I3 Model I3D Section OEM ISOLATED SIGNAL CONVERTERS www fema es 11 Notes...

Страница 12: ......

Отзывы: