FEMA ELECTRÓNICA . Series K . K40-A

15

1.16 

Precautions on installation

1.17 

Factory configuration

1.18 Warranty

Manufacturer  FEMA ELECTRÓNICA, S.A.

 

 

Altimira 14 - Pol. Ind. Santiga

 

 

E08210 - Barberà del Vallès 

 

 

BARCELONA  - SPAIN

 

 

www.fema.es - [email protected]

Products  

K40-A

The manufacturer declares that the instruments indicated comply with the 

directives and rules indicated below.
Electromagnetic compatibility directive 2014/30/EU

 

Low voltage directive 2014/35/EU

 

Directive ROHS 2011/65/EU

Security rules EN-61010-1

Instrument  

Fixed

 

 

Permanently connected

 

Pollution degree 1 and 2 (without condensation) 

 

Isolation  

Double

 

Category 

CAT-III up to 300 Vac

 

 

CAT-II up to 600 Vac

Electromagnetic compatibility rules EN-61326-1

EM environment  Industrial

Immunity levels

EN-61000-4-2  By contact ±4 KV 

Criteria B

 

 

By air ±8 KV 

Criteria B

EN-61000-4-3    

Criteria A

EN-61000-4-4   On AC power lines : ±2 KV 

Criteria B

 

 

On DC power lines : ±2 KV 

Criteria B

 

 

On signal lines : ±1 KV 

Criteria B

EN-61000-4-5  Between AC power lines ±1 KV 

Criteria B

 

 

Between AC power lines and earth ±2 KV 

Criteria B

 

 

Between DC power lines ±1 KV 

Criteria B

 

 

Between DC power lines and earth ±2 KV 

Criteria B

 

 

Between signal lines and earth ±1 KV 

Criteria B 

EN-61000-4-6   

Criteria A

EN-61000-4-8  30 A/m at 50/60 Hz 

Criteria A

EN-61000-4-11  0 % 1 cycle 

Criteria A

 

 

40 % 10 cycles 

Criteria A

 

 

70 % 25 cycles 

Criteria B

 

 

0 % 250 cycles 

Criteria B

Emission levels

CISPR 11  

Instrument Class A, Group 1  

Criteria A

Barberà del Vallès October 2017

 

Xavier Juncà - Product Manager

According  to  directive  2012/19/EU,  electronic  equip-

ment  must  be  recycled  in  a  selective  and  controlled 

way at the end of its useful life.

1.19 

CE declaration of conformity

This instrument is warranted against all manufacturing defects for a 

period of 24 MONTHS from the shipment date. This warranty does 

not apply in case of misuse, accident or manipulation by non-autho

-

rized personnel. In case of malfunction get in contact with your local 

provider to arrange for repair. Within the warranty period and after 

examination by the manufacturer, the unit will be repaired or substi

-

tuted when found to be defective. The scope of this warranty is lim

-

ited to the repair cost of the instrument, not being the manufacturer 

eligible for responsibility on additional damages or costs.

Scale 

0/600 Vac

Scaling and decimal point 

0/600 Vac = 0/600.0

Alarms 1,2 and 3

   Active 

off (disabled)

   Type 

alarm as maximum

   Setpoint 

1000

   Hysteresis 

0 counts

   Activation delay 

0.0 seconds

   Deactivation delay 

0.0 seconds

   Setpoint 2 

off

   Inverted relay 

off

   Locked alarms 

off

Display

   Fixed digits 

off

   Average 

off

   Steps 

off

   Left zeros 

off

   Maximum memory 

-1999

   Minimum memory 

9999

   Peak&Hold 

off

Tools

   ‘Fast access’ 

off

   ‘On power-up’ 

      Delay 

0 seconds

   Key LE 

no function

   Password 

off

   Brightness 

3

This instrument has been designed and verified conforming to the 61010-1 CE Security 

Regulation, for industrial applications. Installation of this instrument must be performed 

by qualified personnel only. This manual contains the appropriate information for the in

-

stallation. Using the instrument in ways not specified by the manufacturer may lead to a 

reduction of the specified protection level. Disconnect the instrument from power before 

starting any maintenance and / or installation action. The instrument does not have a gen

-

eral switch and will start operation as soon as power is connected. The instrument does 

not have protection fuse, the fuse must be added during installation.

The instrument is designed to be panel mounted. An appropriate ventilation of the in

-

strument must be assured. Do not expose the instrument to excess of humidity. Maintain 

clean by using a humid rag and do NOT use abrasive products such as alcohols, solvents, 

etc.

General recommendations for electrical installations apply, and for proper functionality 

Risk of electrical shock. Instrument terminals can be connected 

to dangerous voltage.

Instrument protected with double isolation. No earth connection 

required.

Instrument conforms to CE rules and regulations. 

we recommend : if possible, install the instrument far from electrical noise or magnetic 

field generators such as power relays, electrical motors, speed variators, ... If possible, do 

not install along the same conduits power cables (power, motor controllers, electrovalves, 

...) together with signal and/or control cables.

Before proceeding to the power connection, verify that the voltage level available matches 

the power levels indicated in the label on the instrument.

In case of fire, disconnect the instrument from the power line, fire alarm according to local 

rules, disconnect the air conditioning, attack fire with carbonic snow, never with water.

Содержание K K40-A Series

Страница 1: ...x 48 mm size 1 8 DIN Reading with 4 digit dis play Fast access to alarm setpoints on power up function measure function configurable reading brightness Universal AC and DC power Up to 3 optional modules for output and control relays tran sistor control SSR analog outputs Modbus RTU communications RS 485 ASCII RS 232 www fema es Tel 34 93 729 6004 info fema es User s Manual ELECTRONICS FOR INDUSTRI...

Страница 2: ... for maximum and minimum reading password protection 5 brightness levels 1 1 How to order Index 1 Panel meter K40 A 2 1 1 How to order 2 1 2 Front view 3 1 3 Rear view 3 1 4 Power connections 3 1 5 Signal connections AC voltage 3 1 6 Signal connections AC current 3 1 7 Technical specifications 4 1 8 Mechanical dimensions mm 5 1 9 Coupling AC or AC DC 5 1 10 How to operate the menus 6 1 11 Messages...

Страница 3: ...e section 1 4 Detail of the plug in screw terminals provided with the instrument The instrument is provided with all terminals needed both male and female To configure the voltage AC measure select the jumper for the de sired scale as indicated in the table below Then activate the selected scale in the configuration menu see section 1 12 1 and connect the input signal to the signal terminals Scale...

Страница 4: ...z for AC currents minimum frequency 25 Hz for reading oscillation 1 count 1 7 Technical specifications Power power H 85 a 265 Vac dc power L 11 a 60 Vdc y 24 48 Vac isolation 2500 Veff with power H 1500 Veff with power L all units tested during 60 seconds consumption 1 5 W only meter 4 0 W meter with options Configuration 3 buttons front keypad and rear jumper Front protection IP65 Output and cont...

Страница 5: ...Password configuration block 1 12 10 Measure yes 1 12 5 Peak Hold yes 1 12 4 Display brightness 5 levels 1 12 13 Table 4 Functions included 1 7 Technical specifications cont 1 8 Mechanical dimensions mm 1 9 Coupling AC or AC DC The instrument provides and internal jumper to block the DC component of the signal By default the blocking of the DC com ponent is disabled To block the DC component of th...

Страница 6: ... through the different menu op tions At menus with numerical value entries it modifies the digit selected by increasing its value to 0 1 2 3 4 5 6 7 8 9 Key LE 3 inside the menus the LE 3 key functions as the ES CAPE key It leaves the selected menu and eventually will leave the whole menu When leaving the configuration menu with the LE 3 key the changed parameters are activated At menus with numer...

Страница 7: ... low F Lo function Then the following sequence will start message with signal type mA or Vdc message wait WAIt in flash mode after 5 seconds message ok oK appears at this point press key SQ the menu returns to menu entry Field Low F Lo The instrument has read the input signal and automatically config ures the Input low I Lo for you Repeat the process generating the maximum input signal and access ...

Страница 8: ...hing of the alarm relays due to fluctuating input signals around the set point at Activation delay dEL 0 configure the delay to apply before alarm activation The activation delay starts counting when the set point value is passed Value from 0 0 to 99 9 seconds at Deactivation delay dEL 1 configure the delay to apply before alarm deactivation The deactivation delay starts counting when the setpoint...

Страница 9: ...displays the maximum reading value stored in memory It also provides a way to reset the value This parameter is eligible for configuration through the Fast access menu see section 1 12 5 the Memory of minimum MAX function displays the minimum reading value stored in memory It also provides a way to reset the value This parameter is eligible for configuration through the Fast access menu see sectio...

Страница 10: ... Setpoint 3 Measure The UP 5 key at the front of the instrument gives access to a list of functions configurable by the operator See section 1 10 for an ex planation on how to operate the fast access menu The Key UP Fast access K uP menu allows to select which func tions will be accessible through the fast access menu Select on to activate each function the Setpoint 1 ALr1 function allows to visua...

Страница 11: ...ent light intensity Menus OPt 1 OPt 2 and OPt 3 give access to the configuration menus of the output and control modules installed at slots Opt 1 Opt 2 and Opt 3 See section 2 for a list of output and control modules available for each slot The configuration menu of each module is described at the User s Manual of each module At the Factory reset FAct menu select yes to load the default factory co...

Страница 12: ...m 1 Setpoint Hysteresis Active Alarm type Activation delay Setpoint 2 Deactivation delay Left zeros Steps Average filters 0 0 to 99 9 Display Fixed digits Memory of maximum Memory of minimum Peak Hold Time seconds Alarm 2 menu Alarm 3 menu Relay inverted Locked alarm Scale 600 Vac Scale 100 Vac Scale 10 Vac Scale 1 Vac Scale 100 mVac Scale 5 Aac Scale 1 Aac Field correction Correction high Correct...

Страница 13: ...tpoint 3 Measure On power up Delay Seconds Key LE Alarm unlock No function Option 1 Configuration menu for the module installed at Opt 1 Option 2 Configuration menu for the module installed at Opt 2 Option 3 Configuration menu for the module installed at Opt 3 Minimum Brightness Maximum Standard Password Firmware version Factory reset AC deadband ...

Страница 14: ...qualified personnel only To open the housing use a flat screwdriver to free the fixation clips if possible in the following order D C B and A Remove the front cover Let the inside of the instrument slide out of the housing To reinsert the instrument make sure that all modules are correctly connected to the pins on the display module Place all the set into the housing assuring that the modules corr...

Страница 15: ... manufacturer eligible for responsibility on additional damages or costs Scale 0 600 Vac Scaling and decimal point 0 600 Vac 0 600 0 Alarms 1 2 and 3 Active off disabled Type alarm as maximum Setpoint 1000 Hysteresis 0 counts Activation delay 0 0 seconds Deactivation delay 0 0 seconds Setpoint 2 off Inverted relay off Locked alarms off Display Fixed digits off Average off Steps off Left zeros off ...

Страница 16: ...ntinuous Isolation 3500 Veff Type of terminal plug in screw terminal pitch 5 08 mm Slots allowed Opt 1 Opt 2 Opt 3 Terminal A Common Terminal B NO Normally open Terminal C NC Normally closed Power Opt 2 Opt 1 Opt 3 A B C A B C Signal A B C The T1 module provides 1 transistor output to install at digital panel meters from Series K up to a maximum of 3 transistors in a single meter Configuration is ...

Страница 17: ... special configuration Terminal A Vexc Terminal B Signal in mA or Vdc Terminal C GND Jumper M closed for mA Jumper V closed for Vdc For more information http fema es docs 4254_SERIES_M K S_ OPTIONS_manual_i pdf Power Opt 2 Opt 1 Opt 3 A B C A B C Signal A B C MV MV MV The SSR module provides 1 output to control SSR relays to install at digital panel meters from Series K up to a maximum of 3 SSR co...

Страница 18: ... Opt 2 Opt 1 Opt 3 B A G B A G Signal B A G Terminal B B signal from RS 485 bus Terminal A A signal from RS 485 bus Terminal G GND For more information http fema es docs 4254_SERIES_M K S_ OPTIONS_manual_i pdf Protocol Modbus RTU Functions implemented 4 Read_Input_Registers Bus type RS 485 up to 57 6 Kbps Isolation 1000 Vdc Slots allowed Opt 1 Opt 2 Opt 3 The RTU module provides a Modbus RTU commu...

Страница 19: ...programs Access to display values alarm status memory of maximum and minimum alarm setpoints Configuration from instrument front keypad through menu entries Opt 1 Opt 2 or Opt 3 depending on the position the module is installed The S2 module can be ordered pre installed into a Series M panel meter or standalone for delayed installation as it does not require soldering or special configuration Rela...

Страница 20: ... without front key pad To configure the instrument remove the meter from the panel and remove the front filter Inter nal press buttons for configuration are accessible Optionally request the instrument preconfigured from factory Without front keypad 3 1 Option NBT ...

Страница 21: ...older 4 1 THM benchtop housing Adapter96 x 96 mmfor96 x 48 mm instruments Adapter for DIN rail mount for Series M and Series K of panel meters Front IP65 protector for Series M and Series K of panel meters Wall mount housing Together with the KIP protector offer a full IP65 protection For Series M and Series K of panel meters 4 2 Adapter DRA M 4 3 Adapter KA96 4 4 WME housing 4 5 Protector KIP ...

Страница 22: ...FEMA ELECTRÓNICA Series K K40 A 22 Notes ...

Страница 23: ...FEMA ELECTRÓNICA Series K K40 A 23 Notes ...

Страница 24: ......

Отзывы: