![Felder RL 250 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/felder/rl-250/rl-250_user-manual_3923111028.webp)
28
!
Š
Dust Extractor
RL 250/RL 300
Pulse-jet cleaning pneumatic diagram
22 Pulse-jet cleaning pneumatic diagram
Pos.
Art. Nr.
Pcs.
Description
001
5603001
1
Compressed air tank
002
56021029
3
Solenoid valve VEP508 1“ 230VAC MECAIR
003
5602913
1
Filter pressure regulator NL G3/4 with pressure gauge
004
5775210
1
Spherical valve ¾ inch
005
5775020
1
¾ inch brass one-way valve
006
5775018
1
Hose connection nipple ¾ inch - 19 mm No. 461
007
577809703
Pipe ¾ inch
!
Spherical valve
Š
Bleed screw
Fig. 6: Compressed air supply connection
Removing the pressure from the pulse-jet cleaning
process:
1.
Close the spherical valve.
2.
Loosen the bleed screw until the compressed air
escapes.
3.
If the pressure gauge is on 0 and no further com-
pressed air escapes, then the compressed air unit
(tank, valve and pipe) is completely empty.
4.
Close the bleed screw again.