![Felder RL 250 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/felder/rl-250/rl-250_user-manual_3923111022.webp)
22
Dust Extractor
RL 250/RL 300
Attention! Regularly document maintenance and servicing work!
Ignition sources and electrostatic charges are to be avoided when servicing and maintaining the device.
Only use original spare parts. Do not alter the device in any way. Alterations would result in losing the
type approval!
Maintenance/Removing the collected materials
15 Maintenance
Interval
Task to accomplish
Daily
Collecting container level control
Visual check to see if there are any apparent defects
Water pressure gauge extinguisher
Compressed air pressure gauge for dedusting
Monthly*
Leak control
Damage and function check
Annually**
Main inspection and air flow rate control
Compressed air container visual check (for corrosion)
* = To be carried out by a skilled professional ** = To be carried out by a qualified professional
16 Removing the collected materials
Dust and woodshavings are collected into the collecting
containers during the vacuum process. The level indica-
tion is controlled on the level tube. Only a total volume
of 500 litres of dust may be stored. If during the level
control, a collecting container is shown to be full (cor-
responds to 166 L), switch off the device. By pressing
the cleaning key, a jet of compressed air is triggered,
which removes dust and woodshavings from the filter.
This is to ensure that dust and woodshavings will not
fall out of the device once the collecting containers have
been removed. Please note that there are three cleaning
cycles! Wait for the third jet of compressed air! Release
the collecting containers onto the floor by opening the
locking clamp and roll them forwards.
The part of the plastic sack folded over the edge of the
collecting container is removed carefully, twisted and
closed. The sack is removed carefully and disposed of
according to the local regulations.
When inserting a new sack, ensure that the bag lies
smoothly against the walls and that there are as few
creases as possible on the upper edge of the collecting
container!
Warning! Danger of dust inhalation:
Always use a dust respirator (filter mask with a particle collector, Class 2) when carrying out this task.
Prevent uninvolved people from being exposed to the dust pollution.
Avoid ignition sources and electrostatic charging.
Only use original sacks.
Operating the machine without the filling sacks is forbidden as dust and woodshavings can clog the vacu-
um differential duct!
Dust and shavings must be disposed of according to the regulations of the country where the
machine is installed.
Содержание RL 250
Страница 33: ...33 Dust Extractor RL 250 RL 300...
Страница 34: ...34 Dust Extractor RL 250 RL 300...
Страница 35: ...35 Absaugger t RL 250 RL 300 Dust Extractor RL 250 RL 300...