background image

13

en

Assembly instructions.

Before mounting or replacing application tools or accessories, remove the bat-
tery. 

This preventive safety measure rules out the danger of injuries through 

accidental starting of the power tool.

Mounting the auxiliary handle (figure 2).

To loosen the clamping strap of the auxiliary handle, turn the handle counterclockwise.
Slide the strap of the auxiliary handle in the desired working position onto the collar until the 
teeth engage into the recesses, and then tighten.

WARNING

1.

2.

3.

1.

4.

3.

2.

5.

Fig. 2

Auxiliary handle

OBJ_BUCH-0000000371-001.book  Page 13  Wednesday, February 20, 2019  9:29 AM

Содержание ASCM18QM Series

Страница 1: ...IN Canadian Power Tool Company 323 Traders Boulevard East Mississauga Ontario L4Z 2E5 Telephone 905 8901390 Phone 1 800 265 2581 www fein com Headquarter C E Fein GmbH Hans Fein Stra e 81 D 73529 Schw...

Страница 2: ...2 Instruction Manual Mode d emploi Instrucciones de uso en 3 fr 25 es 47 OBJ_BUCH 0000000371 001 book Page 2 Wednesday February 20 2019 9 29 AM...

Страница 3: ...s can cause you to lose control 2 Electrical safety a Power tool plugs must match the outlet Never modify the plug in any way Do not use any adapter plugs with earthed grounded power tools Unmodified...

Страница 4: ...urce and or remove the battery pack if detachable from the power tool before making any adjustments chang ing accessories or storing power tools Such preventive safety measures reduce the risk of star...

Страница 5: ...ehaviour resulting in fire explosion or risk of injury f Do not expose a battery pack or tool to fire or excessive temperature Exposure to fire or temperature above 130 C may cause explosion g Follow...

Страница 6: ...capable of stopping small abrasive or workpiece fragments The safety glasses must be capable of protecting against flying particles generated by the vari ous operations Prolonged exposure to high inte...

Страница 7: ...or other chemical materials in the filter bag or the vac filter can self ignite under unfavorable conditions such as spark ing from sanding metal continuous sunlight or high ambient temperatures To pr...

Страница 8: ...nd emission ASCM18QM A weighted emission pressure power level measured at the workplace LpA re 20 Pa in decibels 73 Measuring uncertainty KpA in decibels 3 Measured A weighted sound power level LwA re...

Страница 9: ...gainst heat e g against continuous intense sunlight Observe the notes in the text aside Switching on Switching off This symbol confirms the certification of this product for the USA and Canada Confirm...

Страница 10: ...wer Angle width U V Electric voltage f Hz Frequency I A Electric current intensity m kg lbs Mass l ft in Length width height depth diameter or thread ft in Diameter of a round part K Uncertainty m s2...

Страница 11: ...ing of the power tool Not all accessories described or shown in this instruction manual will be included with your power tool WARNING Gripping surface Gripping surface Battery Bit garage Belt hook Rot...

Страница 12: ...m Chuck clamping range 1 16 1 2 in 1 5 13 mm Screw diameter 3 8 in 10 mm Weight according to EPTA Procedure 01 power tool without battery and application tool 2 64 lbs 1 2 kg Weight according to EPTA...

Страница 13: ...the power tool Mounting the auxiliary handle figure 2 To loosen the clamping strap of the auxiliary handle turn the handle counterclockwise Slide the strap of the auxiliary handle in the desired worki...

Страница 14: ...xert any force when doing this Connect the battery charger to a socket out let slide the battery onto the battery charger and charge the battery After the charging process is over insert the battery i...

Страница 15: ...bit garage fit the spacer as well as the bit garage to the tool and fasten both with the screw To mount the belt hook together with the bit garage fit the spacer the belt hook and the bit garage to t...

Страница 16: ...nto the spindle Release the ring Turn the drill chuck to lock it Removing the drill chuck figure 6 When changing the drill chuck avoid debris from entering the drill chuck and the spindle Slide the ri...

Страница 17: ...es through accidental starting of the power tool Mounting application tools figure 7 Open the keyless drill chuck Afterwards insert the desired application tool Tighten the keyless drill chuck Mountin...

Страница 18: ...h only when the machine is at a complete stop Always slide the gear selector to the stop Otherwise the machine can become dam aged Set the desired operating mode For drilling set the operating mode se...

Страница 19: ...h and press it again for the next screw driving operation The audio signal can be switched on and off The electronic shut off is deactivated when working in the torque level To achieve good working re...

Страница 20: ...ys slide the gear selector to the stop Otherwise the machine can become dam aged You can adjust 4 gear settings Set the lowest gear setting to work at low speed with high torque This gear setting is s...

Отзывы: