13
en
Assembly instructions.
Before mounting or replacing application tools or accessories, remove the bat-
tery.
This preventive safety measure rules out the danger of injuries through
accidental starting of the power tool.
For all work or when changing application tools, always wear protective gloves.
Danger of injury from the sharp edges of the application tools. Application tools
can become very hot while working. Danger of burns!
Changing the tool
Do not switch the power tool
on while the clamping lever is
open.
Otherwise there is danger of crushes or
contusions to the hand and fingers.
Do not actuate the clamping
lever while the power tool is
running.
Otherwise there is danger of injury.
Do not reach into the area of
the clamping jaws.
Otherwise
there is danger of crushes or contusions to
the fingers.
Do not operate the power tool
with open clamping jaws and
without an application tool!
This could dam-
age the power tool.
When the clamping jaws are
open before the application
tool is inserted, pivot the clamping lever
toward the front and then back again.
The
clamping jaws are closed now. The application
tool can be inserted.
Inserting the application tool (figure 4).
Clean the tool holder and the application tool.
In the starting position, the clamping jaws in
the tool holder are together. In this position,
the application tool can be clipped-in easily.
WARNING
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
2.
3.
1.
Fig. 4
OBJ_BUCH-0000000251-001.book Page 13 Monday, February 8, 2016 12:04 PM