7
en
Emission values for sound and vibration
(Two-figure – specifications as per ISO 4871)
Sound emission
AFMM18(QSL)
A-weighted emission pressure power level measured at the workplace
L
pA
(re 20 μPa), in decibels
74
Measuring uncertainty
K
pA
, in decibels
3
Measured A-weighted sound power level
L
wA
(re 1 pW), in decibels
85
Measuring uncertainty
K
wA
, in decibels
3
C-weighted peak sound pressure level measured at the workplace
L
pCpeak
,
in decibels
87
Measuring uncertainty
K
pCpeak
, in decibels
3
REMARK: The sum of the measured emission value and respective measuring inaccuracy
represents the upper limit of the values that can occur during measuring.
Wear hearing protection!
Measured values determined in accordance with the corresponding product standard.
Vibration
Classification of FEIN
application tools accord-
ing to vibration class
Weighted
acceleration*
VC0
< 2.5 m/s
2
< 8 ft/s
2
VC1
< 5 m/s
2
< 16 ft/s
2
VC2
< 7 m/s
2
< 23 ft/s
2
VC3
< 10 m/s
2
< 33 ft/s
2
VC4
< 15 m/s
2
< 50 ft/s
2
VC5
> 15 m/s
2
> 50 ft/s
2
K
a
1.5 m/s
2
4.92 ft/s
2
* These values are based on a work cycle consist-
ing of no-load and full-load operation of the same
duration.
For information on the vibration class assigned to
the application tool, please refer to the enclosed
data sheet 3 41 30 443 06 0.
OBJ_BUCH-0000000251-001.book Page 7 Monday, February 8, 2016 12:04 PM