background image

Manual 

VEK S4

10

03/09 

FEIG ELECTRONIC GmbH

2.4 Output 

modes

The following output modes can be set for the four open collector outputs:

Output mode

Description

Standard output

Normal output mode for presence or direction detection

Group fault message

Output indicates loop faults from all loops

always off

Output always turned off

always on

Output always turned on

Simulation

Output switches constantly, e.g. for testing purposes

Inverted

 or 

non-inverted

 signal output can be selected for all output modes.

In the case of standard output the loop faults of the respective channel can be output together with the
logical signal. Which fault is additionally indicated can be set to loop fault (break/short), loop frequency
outside frequency band and calibration procedure.

Factory default setting

: Standard 

output,

Signals not inverted,
Respond to loop fault

The interface can be used to temporarily turn the outputs on or off. This allows you to implement control
tasks such as controlling traffic lights or variable message signs.

In simulation mode the output is constantly repeated according to the following scheme:

- The signal duration corresponds to the set minimum on duration
- The pause time corresponds to the set on delay. If no on-delay is set (0 ms), an idle time of 20s is

assumed.

For the factory set time behavior of the output signals this means a pulse signal of 200 ms duration and an
idle time of 20 s.

2.5  Time response of the output signals

On-delay, minimum on duration and off-delay for the hardware output signals can be set in 100 ms
increments over a range of 0...25500ms.

Factory default setting

:  

On-delay 0 ms
Off-delay 0 ms
Minimum on duration 200 ms

Loop busy

Output signal

t

on

t

d

 

 t

dmin

t

off

t

on

: On 

delay

t

off

: Off 

delay

t

dmin

 :

Minimum on duration

t

d

 :

Signal duration

Содержание VEK S4

Страница 1: ...VEK S4 Manual 2009 03 31 S4_Handbuch_GB_090331 doc Traffic Detector VEK S4...

Страница 2: ...e errors can never be completely precluded in spite of all our efforts we are always grateful for corrections and suggestions The installation recommendations contained in this guide assume the most f...

Страница 3: ...14 4 3 Factory settings 15 4 4 Synchronisation display 16 4 5 DIP switches 16 5 Case 18 5 1 Dimensions 18 5 2 Opening the case 19 6 Technical data 20 7 Connector and pin assignment 21 7 1 Power suppl...

Страница 4: ...nection RS485 interface 4 Open Drain outputs Other features compact plastic case mounting on DIN rail avoidance of reciprocal influencing of the channels using multiplexing methods avoidance of recipr...

Страница 5: ...cle data The typical frequency change for vehicles and its time course on two induction loops with known geometric dimensions are used for deriving the following factors vehicle class vehicle speed ve...

Страница 6: ...methods The connected induction loops are switched on and off in rapid sequence so that current flows only through one loop at a time This prevents mutual interference between the loops of a detector...

Страница 7: ...Detector Nr 3 can in the worst case affect all the loops of Detectors 1 2 4 and themselves be affected by these loops 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 VEK M4D Induction loops on multiple detec...

Страница 8: ...the recommended range see Section 6 Technical data the frequency band setting can be restricted The detector may calibrate to a different frequency than shown in the above table This is not a problem...

Страница 9: ...tion modul 1 Classifaction modul 2 Signals OpenCollector 3 Counter ever class and directoin OpenCollector 4 OpenCollector 1 OpenCollector 2 Loop allocation is firm Counter ever class ans direction Aug...

Страница 10: ...ng Standard output Signals not inverted Respond to loop fault The interface can be used to temporarily turn the outputs on or off This allows you to implement control tasks such as controlling traffic...

Страница 11: ...S defined in the VEK S3 are also supported In these cases one VEK S4 behaves like two separately addressable VEK S3 units Mixed operation of VEK S3 and VEK S4 on a common bus is not recommended Defaul...

Страница 12: ...ame detector are preferably assigned to different channel numbers Otherwise the multiplexing sequence must be changed over during the commissioning 1 5 Multiplexing methods 1 6 Synchronisation 2 2 Mul...

Страница 13: ...of the speed and length measurements should be made with reference to average values obtained from several measuring cycles 12 Speed The speeds of the vehicles must be measured with a sufficiently acc...

Страница 14: ...key LED display in binary code Function 1x short Uses LEDs 1 4 to display the hardware address set with DIP switches 1 4 1x long Generates a hardware reset and before that displays the set hardware a...

Страница 15: ...loop errors Standard hardware output for loop assignment Loop parameters Classification module 1 and 2 Head gap 250 cm TLS II loop Length adjustment 0 Amplitude factor 100 TLS II loop Loop length 100...

Страница 16: ...for the CAN bus and RS485 interface The DIP switches are located inside the enclosure As shipped all DIP switches are in the OFF position 1 2 3 4 5 6 7 8 1 ON Address 0 15 RS485 Pullup Pulldown Bus t...

Страница 17: ...etector with a 120 resistor Set DIP switch 7 to ON in the last detector In addition the two RS485 signal lines B and A must be connected once to 5V resp to GND with a 470 resistor each If this has not...

Страница 18: ...Manual VEK S4 18 03 09 FEIG ELECTRONIC GmbH 5 Case 5 1 Dimensions...

Страница 19: ...pening Loosen upper section A by gently pressing with a screwdriver on the side springs at B Remove upper section Closing Check orientation note contact surface C and PE contact D Guide circuit board...

Страница 20: ...esolution 1 km h Length measurement 10 dm to 250 dm for constant vehicle speed Tolerance 3 dm Vehicle classification 8 1 classes Car car with trailer truck truck with trailer van bus motorcycle articu...

Страница 21: ...lso connected to contacts of the front side ribbon cable terminal This means the supply and interface connections can also be made either using the plug terminal or ribbon cable When multiple detector...

Страница 22: ...nd interface screwless terminals 7 4 Outputs OC1 OC2 OC3 OC4 The Open Collector outputs are short circuit protected When a signal is output the outputs switch on Low active Vbb U 45V Last OC1 4 7 5 PE...

Страница 23: ...s 4 plug terminals configured 1m ribbon cable with 16 spring action contacts and an additional spring action contact The ribbon cable is trimmed to length by the user for the number of detectors If th...

Страница 24: ...ly must be fulfill the requirements for SELV and limited power sources according to EN 60950 1 Wiring startup maintenance measurement and setting work on the traffic detector are to be performed only...

Страница 25: ...of the classification modules Scanning mode Interf filter Response time 4 loops on 16 ms 2 loops on 8 ms 1 loops on 4 ms 4 loops off 8 ms Default or factory setting 2 loops off 4 ms 1 loop off 2 ms It...

Страница 26: ...te The response thresholds of the VEK S4 are different from the response threshold of the VEK M4D for the same sensitivity f f 10 3 Hysteresis drop 4Ch In order to avoid an intermediate loss of the oc...

Страница 27: ...ignal for 75 drop value threshold Detuning by vehicle Output signal 10 4 Holding time 4Ch Separate holding times between 1 and 255 minutes can be set for each channel on the detector A zero setting me...

Страница 28: ...puts to the Open Drain outputs can be adjusted The assignment meters can be invoked via the interface For counting in time intervals the counting result must be determined from the meter readings at t...

Страница 29: ...with wrong driver situations see appendix BS both loops Allocation 2 loop Correct behavior with column traffic should not seem to Rangierer FE Feig left 1 loop Correct behavior with column traffic an...

Страница 30: ...well for Loops 3 and 4 or other loop combinations Explanations for the table xx Direction logic gray logic with incorrect count in this traffic situation ___ Imp Direction pulse Imp Direction pulse in...

Страница 31: ...B F1 F2 FE SF BS Ri1 Ri2 1 2 on on 1 2 on Imp Imp Imp 1 2 off Imp Imp 1 2 on 1 2 off ___ Imp 1 2 on Imp Imp Imp 1 2 off Imp Imp 1 2 off off Imp Imp 10 5 1 3 Wrong way driver 1 PB D2 D1 DB F1 F2 FE SF...

Страница 32: ...ver 2 PB D2 D1 DB F1 F2 FE SF BS Ri1 Ri2 1 2 on on 1 2 on Imp Imp Imp 1 2 off Imp Imp 1 2 on 1 2 off ___ Imp 1 2 off off ___ Imp 10 5 1 5 Maneuverer 1 PB D2 D1 DB F1 F2 FE SF BS Ri1 Ri2 1 2 on on 1 2...

Страница 33: ...S4 FEIG ELECTRONIC GmbH 03 09 33 10 5 1 6 Maneuverer 2 PB D2 D1 DB F1 F2 FE SF BS Ri1 Ri2 1 2 on on 1 2 on Imp Imp Imp 1 2 off Imp Imp 1 2 on 1 2 off Imp 1 2 on Imp Imp Imp 1 2 off Imp Imp 1 2 off of...

Страница 34: ...p Imp 1 2 off Imp Imp 1 2 on 1 2 off ___ Imp 1 2 off off ___ Imp 10 5 1 8 Cross traffic PB D2 D1 DB F1 F2 FE SF BS Ri1 Ri2 1 2 on on 1 2 on Imp Imp Imp 1 2 off Imp Imp 1 2 on 1 2 off ___ Imp 1 2 off o...

Страница 35: ...rmitted In travel direction 2 1 even vehicles in traffic line situations are correctly counted whereby the vehicle gap must always enable a loop Logic for travel direction 1 2 The counter pulse arrive...

Страница 36: ...Manual VEK S4 36 03 09 FEIG ELECTRONIC GmbH 11 Notes...

Отзывы: