Manual
VEK S4
26
03/09
FEIG ELECTRONIC GmbH
Parameter
value
Response
threshold
value
Sensitivity (
∆
f/f)
0
4
0.02 %
maximum
sensitivity
1
10
0.04 %
2
20
0.08 %
3
30
0.13 %
4
40
0.17 %
5
50
0.20 %
:
:
11
110
0.46 %
12
120
0.5 %
(Factory setting)
13
130
0.54 %
:
:
41
410
1.71 %
42
420
1.75 %
43
430
1.79 %
:
:
100
1000
4.17%
:
:
255
2550
10.63 %
lowest
sensitivity
Note: The response thresholds of the VEK S4 are different from the response threshold of the VEK M4D for
the same sensitivity (
∆
f/f).
10.3 Hysteresis drop (4Ch)
In order to avoid an intermediate loss of the occupied signal for vehicles with a high undercarriage such as
articulated buses, trams, trucks with trailers etc, it is possible to modify the switching hystereses. An
interruption-free detection of critical vehicles is then also possible with low closure resistance setting. The
drop value threshold factory setting is 75%.