Start-up protocol - Digital Counter Unit VEK CN1-1
Location: ____________________________________________________
Date:
____________ Name: ________________________________
FEIG ELECTRONIC GmbH * D-35781 Weilburg * Lange Str. 4 * Tel.: +496471/3109-0 * Fax: +496471/3109-99
Hold M 2 s in normal operation
→
Display alternating
SYS
and program version (e.g.
A03
)
Hold
∧
,
∨
→
change settings
Hold
∧
,
∨
long
→
fast scroll
Hold M 2 s
→
save
Hold M short
→
next menu item
Hold two simultaneously
→
back to normal operation
Display
Menu item
Setting
Program Version
Vers.: __________
(read only)
S oc
Threshold
0...9.999
Value: __________
HYS
Counter Hysteresis
1...250
Value: __________
SkP~
Upper Counter Threshold
0...9.999
Value: __________
SkP_
Lower Counter Threshold
0...-999
Value: __________
inP1
Input Function 1
Add
increment
Sub
decrement
rEs
reset
no
.
F
no function
inP2
Input Function 2
Add
increment
Sub
decrement
rEs
reset
no
.
F
no function
inP3
Input Function 3
Add
increment
Sub
decrement
rEs
reset
no
.
F
no function
inP4
Input Function 4
Add
increment
Sub
decrement
rEs
reset
no
.
F
no function
rEL
Output Function
oc
.
on
normally closed
Fr
.
on
normally
open
LoPo
Power Saving Mode
off
off (Display on)
on